kPa.
ULPG The gas pressure should be checked to
make sure that the working pressure of the
appliance is 2.75 kPa. The test point is the rapid
burner injector, as shown below.
1. Disconnect the power.
2. Turn on the auxiliary burner and set it to high
flame. Make sure that all the other burners
are turned off.
3. Set the pressure gauge to zero, attach the
hose in order to seal the rapid burner
injector; hold firmly in place and check the
gas pressure by pressing the corresponding
burner control knob and then turn it to the
high flame position.
4. If the pressure is 2.75 kPa, put back the
burner and carry out the final checks as
indicated in this instructions manual.
5. If the pressure is not 2.75 kPa, disconnect
the appliance and check/adjust/replace
the regulator(s) of the LPG cylinder in
accordance with AS/NZS 5601.
Room ventilation
The appliance should be installed in rooms that
have a permanent air supply in accordance
with the standards in force. The room where the
appliance is installed must have enough air flow
for the regular combustion of gas and the
necessary air change in the room itself. The air
vents, protected by grilles, must be the right size
to comply with current regulations and
positioned so that no part of them is obstructed,
14 - INSTALLATION
not even partially.
The room must be kept adequately ventilated in
order to eliminate the heat and humidity
produced by cooking: In particular, after
prolonged use, you are recommended to open
a window or to increase the speed of any fans.
Adaptation to different types of gas
In case of operation with other types of gas, the
burner nozzles must be changed and the
minimum flame adjusted on the gas cocks.
Replacing nozzles
1. Remove the pan supports, burner caps and
flame-spreader crowns to access the burner
cups.
2. Replace the nozzles using a 7-mm wrench
according to the type of gas to be used (see
the "Burner and nozzle characteristics
table").
3. Replace the burners in their respective
housings.
Adjusting the minimum setting for natural gas
1. Light the burner and turn it to the minimum
position.
2. Remove the gas tap knob and turn the
adjustment screw next to the gas cock
91477A095/B