The fuses blow or the circuit breaker of the
residential electrical system trips repeatedly.
• Call Technical Support or an electrician.

INSTALLATION

The appliance must be installed by a
qualified technician and according to
the regulations in force.
Appliance factory set for gas: NG
pressure 1kPa.

Gas connection

See General safety instructions.
General information
This appliance is suitable for use with natural
gas or ULPG (propane / butane) systems.
Refer to the "Burner and nozzle characteristics
table" section for information regarding the
appropriate burner pressure and injector size.
If the appliance is to be connected to natural
gas, the pressure regulator must be fitted to the
gas inlet. A test point (for checking the gas
pressure) is supplied with the regulator, or as a
separate fitting for ULPG (propane) appliances.
The connection of the appliance to the gas
supply must comply with the requirements of
AS5601. A 1/2" BSP connector at the inlet is
recommended. The gas supply line to the
appliance must be of an adequate length to
allow it to be withdrawn sufficiently for
maintenance or disconnection. It must also be:
1 an annealed copper pipe, or:
91477A095/B
There are cracks or fissures in the hob:
• Turn off the appliance immediately,
disconnect the power supply and contact
Technical Support.
2 a 10 mm diameter Class "B" hose compliant
with AS/NZ1869.
The appliance should be installed in such a way
to allow the gas to be turned off and
disconnected for maintenance and the removal
of the appliance as necessary from the gas
supply.
Before putting the appliance into operation,
make sure that all the relevant parts are
positioned correctly.
After installation, the installer MUST check for
gas leaks and test each burner individually to
make sure that the flame is correct. Once all the
burners have been tested individually, light them
all together.
The assistance service does not cover these
adjustments!
It is recommended that at least 2 large burners
be used to check the operating pressure of the
appliance. Make sure the appliance is fixed to
the wall after installation.
Natural gas: The regulator must be fitted to the
1/2" BSP thread on the back of the appliance.
An approved manual shut-off valve must be
installed. The natural gas regulator must be
checked and adjusted to 1.0 kPa after
installation.
ULPG: Can be connected directly to the inlet
fitting. The pressure should be checked and, if
necessary, adjusted to 2.75 kPa. A test point
must be installed between the piping and the
appliance to check that the pressure is 2.75
INSTALLATION - 13