Lapierre FUSION X2 User Manual page 52

Evaporator
Table of Contents

Advertisement

APPENDIX C
5.5 Step 5: STOPPING THE EVAPORATOR
Proceed as follows to shut down the evaporator:
1. Press the [STOP] key on the operating display,
- the key on the evaporator control panel can be
turned to the Off position and removed.
• The program and fans continue to run here, but
the touch screen, while still on, will not accept any
commands.
• It is also possible that the fans stop and restart a
few times.
• The evaporator also continues to evaporate for
several more minutes, so it is important not to turn
Off the concentrate supply to the evaporator in
order to prevent one of the pans from running dry.
6. EMERGENCY MODE
In the event that the OPTIFLAM
that allows the evaporator to continue to operate and then be safely shut down.
The EMERGENCY operation mode should only be used to stop the evaporator.
WE SUGGEST THAT YOU PHOTOCOPY THIS PAGE AND PLACE IT IN PLAIN VIEW NEAR THE
EVAPORATOR.
Here you will find the OPTIFLAM
• [1] selector for Off or On position,
• [2] selector for manual (MAN) or automatic (AUTO) mode,
• [3] potentiometer (rotary knob) for controlling the speed of the PRIMARY
combustion air fan(s),
• [4] potentiometer (rotary knob) for controlling the speed of the
SECONDARY combustion air fan.
To activate the EMERGENCY mode, proceed as follows:
1. Set the MAN/AUTO Selector [2] to manual [MAN].
2. Then control the speed of the combustion fans with the two potentio-
meters [3 and 4].
3. Bring the evaporator to a safe stop.
- The operation of the evaporator is now the same as in MANUAL mode,
except for the combustion chamber and chimney temperatures which
are no longer displayed on the operating display.
Lapierre Equipment |
TM
OPTIFLAM
combustion controller (optional) (continued)
TM
combustion control program stops working, there is an EMERGENCY mode
TM
control box (Illustration 16):
FUSION X
2
EVAPORATOR
| USER MANUAL | Version 01 - September 2022
50
Illustration 15
1
2
3
4
Illustration 16