SECTION 3 Planning the installation of your evaporator (continued)
In this way, when the chimney rests on the FUSION X
highest obstacle on the roof within the specified radius.
NOTE: The chimney must be installed with a minimum clearance of 2 in. (5.08 cm) from all combustible materials.

3.1.2.2 Single wall chimney (non-listed)

From the location where the chimney exhaust will be located on the roof, within a radius of 20 ft. (6.1 m),
identify the highest obstacle. This may, for example, be the roof gable.
Complete TABLE 2: Grid for calculating the minimum chimney height, with the following data.
a. Measure the height from the chimney exhaust location on the roof to the top of the obstacle then add 7 ft.
(2.13 m) to the result (measurement a).
b. Measure the height from the floor to the location of the chimney exhaust on the roof (measurement b).
c. Add the heights measured in a and b. The result is the minimum height of the single-wall chimney that you must
install.
In this way, when the chimney rests on the FUSION X
highest obstacle on the roof within the specified radius.
NOTE: The chimney must be installed with a minimum clearance of 24 in. (60.96 cm) from all combustible
materials.