Page 2
Naturally innovative A leader in equipment and products for the maple syrup industry, LAPIERRE EQUIPMENT distinguishes itself by its ability to innovate and develop high-performance solutions. This is what enables it to make significant changes in production techniques and processes in order to increase crop yield of high-quality syrup.
Please note the information required below when dealing with customer service professionals. You can easily find this information on the data plate on your VISION evaporator as well as on your invoice. You can also refer to Section 1 of this manual for additional information.
When you contact our customer service professionals, it is important to have certain information about your equipment on hand as you will be asked for it. You can easily find this information on the data plate affixed to your VISION evaporator as well as on your invoice.
2.3 REPAIRS AND MAINTENANCE • Stop using the equipment immediately if a malfunction is detected. • Only LAPIERRE EQUIPMENT authorized personnel may carry out repairs on this equipment. • Unauthorized modifications or repairs may result in hazardous operating conditions. These conditions may also cause varying degrees of injury to users.
Add the heights measured in a and b. The result is the minimum height of the LWS listed chimney that you must install. In this way, when the chimney rests on the VISION evaporator, it will be 3 ft. (91.44 cm) above the highest obstacle on the roof within the specified radius.
Add the heights measured in a and b. The result is the minimum height of the single-wall chimney that you must install. In this way, when the chimney rests on the VISION evaporator connection, it is 10 ft. (3.05 m) above the highest obstacle on the roof within the specified radius.
• Your evaporator is supplied with all the necessary components for the safe installation of the LWS listed chimney. However, you must obtain the LWS listed chimney from your LAPIERRE EQUIPMENT representative. • Your evaporator has been designed to operate with a minimum chimney height of 16 ft. (4.88 m), even if the result (c) in the calculation grid above indicates a length of less than 16 ft.
• Check the condition of the evaporator as soon as it arrives. • Although LAPIERRE EQUIPMENT applies rigorous quality control in the plant and before shipping, please note, photograph and advise your LAPIERRE EQUIPMENT representative of any defects or imperfections that may be observed on the day your equipment is received.
1. The front-centre section extends from the front section of the evaporator to the centre leg. 2. The centre-rear section extends from the centre leg of the evaporator to the rear section. Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
- otherwise, the previous levelling steps must be repeated. 4.2 MASONRY AND INSULATION If you have ordered a masonry and insulation kit from LAPIERRE EQUIPMENT, refer to Appendix A: Installation instructions for insulating materials for the procedures and installation steps.
4.5 CONNECTING THE DRAW-OFF COMPONENTS Float box If your VISION evaporator is 18x48, 18x60 or 24x72 in. equipped with the entry-level pans, the float (level control) mechanism is integral with the pan and no float box installation is required. Maple sap connectors All the maple sap evaporator connections required for its operation are in the same package.
The minimum level of each syrup pan for start-up is 2 in. (5.08 cm). • Note that VISION evaporators with 18 x 48, 18 x 60 and 24 x 72 in. accordion boiling pans have only one float to adjust.
- Make sure not to go beyond the middle of the door glass. • Add standard diameter logs on top, preferably no larger than 6 in. (15.24 cm). Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
SECTION 5 Start-up, operation and shutdown procedures (continued) TABLE 3 | Log sizing by model number VISION EVAPORATOR LOGS Model No. Range Overall dimensions Total pan dimensions Length Width Length Width Length F F 01 7- 16 to 18 in *...
- Monitor the temperature of the chimney regularly. - IMPORTANT | At all times, the chimney temperature must not exceed: o 1000 °F (540 °C) for VISION equipment with STANDARD or DELUXE pans, o 1200 °F (650 °C) for VISION equipment with ACCORDIAN PLEATED pans.
• the sealing of the door, • the insulation between the pans and the frame, • the pan insulation joints, if applicable as this is optional. Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
During prolonged storage, even the slightest CLEANING PRODUCT RESIDUE ON ALL COMPONENTS will obviously lead to inconvenience and damage at the beginning of the next season. Rinse each cleaned component thoroughly. Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
SECTION 7 Equipment specifications (continued) ILLUSTRATION 2 | Typical illustration of a 4-legged VISION evaporator VUE DE DESSUS TOP VIEW VUE DE CÔTÉ SIDE VIEW VUE DE FACE FRONT VIEW ILLUSTRATION 3 | Typical illustration of a 6-legged VISION evaporator...
4. Making your warranty claim KEEP YOUR PURCHASE INVOICE It is very important to keep the original invoice for the purchase of your equipment or a legible copy of it. Otherwise, LAPIERRE EQUIPMENT INC. will not accept your warranty claim.
Page 24
COSTS AND LOSSES This warranty does not cover the following costs or losses. 2.2.1 Costs for: • making the product accessible during a service call, Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
Page 25
• This warranty after-sales service operation does not extend the warranty period of the equipment. The end date of the warranty remains the same, i.e., two years from the date of delivery of the product. Warranty certificate: February 2023 (V04) Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
SECTION 9 PARTS AND CONSUMABLES Parts for your VISION evaporator or any other equipment manufactured at LAPIERRE EQUIPMENT are available at our main plant in Saint-Ludger, Quebec, Canada and our service centers in Waterloo, Quebec, Canada and Swanton, Vermont, USA. However, do not hesitate to contact us to locate the distributor nearest you.
• Install the insulation panels on the inside of the evaporator (A). • Cut the insulation panels with an industrial knife or small hand saw. • Follow the instructions in the installation diagrams for the insulation materials of your VISION evaporator. For these instructions, refer to Appendices B to I.
Page 28
• Use a thin layer of high-temperature mortar to cement the bricks. • Install the bricks on sides (B) according to the instructions in the installation diagrams of your VISION evaporator. For these instructions, refer to Appendices B to I.
Page 29
If so, repair the cracks and fill the voids with high-temperature mortar and allow to dry. INSULATING MAT The insulating mat is installed in the rear section of your evaporator (E). Evaporator rear section Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
Page 30
The mat will be held in place, without the use of a fastening mechanism, between the floor and the top fold of the sides (F), as shown in the image below. o Follow the instructions in the installation diagrams of your VISION evaporator model. For these instructions, refer to Appendices B to I.
Page 31
2 in. (5.08 cm) insulating mat, as shown in the following images (I). - Follow the instructions in the installation diagrams for your VISION evaporator model. For these instructions, refer to Appendices B to I.
Page 32
APPENDIX B INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 18 X 48 IN INSULATION PANEL INSTALLATION DIAGRAMS 18 X 48 INCH EVAPORATOR Product code: IB016-180400ST Qty: 1 Qty: 1 Qty: 2 2" 6-1/2" 19-1/8" 3-7/8" 18-1/4" Qty: 1 3-7/8" 19-3/4" TOP VIEW 2-3/4"...
APPENDIX B Insulation material installation diagrams VISION 18 x 48 in. (continued) INSULATION PANEL CUTTING PATTERNS 18 X 48 INCH EVAPORATOR Product code: IB016-180400ST Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
Page 34
APPENDIX B Insulation material installation diagrams VISION 18 x 48 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 18 X 48 INCH EVAPORATOR Product code: IB016-180400ST Qty: 6 Qty: 8 4-1/2" 4-1/2" 4-3/4" 3-7/8" 9" Qty: 2 Qty: 2 4-1/2"...
Page 35
APPENDIX B Insulation material installation diagrams VISION 18 x 48 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 18 X 48 INCH EVAPORATOR Product code: IB016-180400ST TOP VIEW FRONT VIEW 3-3/8" Qty: 2 Qty: 2 2-1/8" 3-1/4" 9" 1-3/4"...
Page 36
APPENDIX B Insulation material installation diagrams VISION 18 x 48 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 18 X 48 INCH EVAPORATOR Product code: IB016-180400ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10" 34" REAR RISER WEDGE Qty: 1 *NOTE:...
Page 37
APPENDIX C INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 18 X 60 IN. INSULATION PANEL INSTALLATION DIAGRAMS 18 X 60 INCH EVAPORATOR Product code: IB016-180500ST Qty: 1 Qty: 1 Qty: 2 2" 6-1/2" 19-1/8" 3-7/8" 18-1/4" Qty: 1 3-7/8" 19-3/4" TOP VIEW 2-3/4"...
APPENDIX C Insulation material installation diagrams vision 18 x 60 in. (continued) INSULATION PANEL CUTTING PATTERNS 18 X 60 INCH EVAPORATOR Product code: IB016-180500ST Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
Page 39
APPENDIX C Insulation material installation diagrams vision 18 x 60 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 18 X 60 INCH EVAPORATOR Product code: IB016-180500ST Qty: 6 Qty: 8 4-1/2" 4-1/2" 5-1/4" 3-7/8" Qty: 2 Qty: 2 2-3/4"...
Page 40
APPENDIX C Insulation material installation diagrams vision 18 x 60 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 18 X 60 INCH EVAPORATOR Product code: IB016-180500ST TOP VIEW FRONT VIEW Qty: 2 Qty: 2 3-3/8" 2-1/8" 3-1/4" 9" 1-3/4"...
Page 41
APPENDIX C Insulation material installation diagrams vision 18 x 60 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 18 X 60 INCH EVAPORATOR Product code: IB016-180500ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10" 42" REAR RISER WEDGE Qty: 1 *NOTE:...
APPENDIX D INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 24 X 72 IN INSULATION PANEL INSTALLATION DIAGRAMS 24 X 72 INCH EVAPORATOR Product code: IB016-240600ST Qty: 2 Qty: 1 Qty: 1 4-7/8" 3-7/8" 21-3/4" 25-3/4" 19-7/8" 21" 12" TOP VIEW Qty: 2 Qty: 2 21-3/4"...
Page 43
APPENDIX D Insulation material installation diagrams VISION 24 x 72 in. (continued) INSULATION PANEL CUTTING PATTERNS 24 X 72 INCH EVAPORATOR Product code: IB016-240600ST Qty: 2 Qty: 2 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 44
APPENDIX D Insulation material installation diagrams VISION 24 x 72 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 24 X 72 INCH EVAPORATOR Product code: IB016-240600ST Qty: 8 Qty: 2 4-1/2" 4-1/2" 3-7/8" 5-1/8" Qty: 8 Qty: 2 4-1/2"...
Page 45
APPENDIX D Insulation material installation diagrams VISION 24 x 72 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 24 X 72 INCH EVAPORATOR Product code: IB016-240600ST TOP VIEW FRONT VIEW Qty: 2 Qty: 1 Qty: 2 Qty: 2 4-1/2"...
Page 46
APPENDIX D Insulation material installation diagrams VISION 24 x 72 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 24 X 72 INCH EVAPORATOR Product code: IB016-240600ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10-1/2" 51" REAR RISER WEDGE Qty: 1 *NOTES :...
Page 47
APPENDIX E INSULATION MATERIAL INSTALLATION DIAGRAMS FOR VISION 24 X 96 IN. INSULATION PANEL INSTALLATION DIAGRAMS FOR SIDES AND INTERIOR FRONT VIEW 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST Qty: 1 Qty: 1 Qty: 2 19-1/8" 3-7/8" 12-1/2" 18-1/4"...
APPENDIX E Insulation material installation diagrams VISION 24 x 96 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR FLOOR RISER 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST Qty: 1 12" 14-1/8" 16-7/8" TOP VIEW Qty: 1 12" 16-7/8" 19-1/2" VIEW OF THE INSULATING...
Page 49
APPENDIX E Insulation material installation diagrams VISION 24 x 96 in. (continued) INSULATION PANEL CUTTING PATTERNS 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST Qty: 2 Qty: 2 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 50
APPENDIX E Insulation material installation diagrams VISION 24 x 96 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST Qty: 8 Qty: 12 Qty: 2 4-1/2" 4-1/2" 4-1/2" 7" 3-1/2" 3-7/8"...
Page 51
APPENDIX E Insulation material installation diagrams VISION 24 x 96 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST TOP VIEW FRONT VIEW Qty: 2 Qty: 2 Qty: 1 Qty: 2 4-3/4"...
Page 52
APPENDIX E Insulation material installation diagrams VISION 24 x 96 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 24 X 96 INCH EVAPORATOR Product code: IB016-240800ST REAR RISER WEDGE Qty: 1 See note opposite* 21" 2" FRONT VIEW TOP VIEW REAR INNER SIDE FACES...
APPENDIX F INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 24 X 120 IN. INSULATION PANEL INSTALLATION DIAGRAMS FOR SIDES AND INTERIOR FRONT VIEW 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST Qty: 1 Qty: 1 Qty: 2 19-1/8" 3-7/8" 18-1/4" 12-1/2" 2"...
Page 54
APPENDIX F Insulation material installation diagrams VISION 24 x 120 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR FLOOR RISER 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST Qty: 1 Qty: 1 12" 12" 15-1/2" 17" 17" 18" TOP VIEW Qty: 1 Qty: 1 6-5/8"...
Page 55
APPENDIX F Insulation material installation diagrams VISION 24 x 120 in. (continued) INSULATION PANEL CUTTING PATTERNS 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST Qty: 2 Qty: 3 Qty: 2 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 56
APPENDIX F Insulation material installation diagrams VISION 24 x 120 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST Qty: 14 Qty: 16 Qty: 2 4-1/2" 4-1/2" 4-1/2" 7-3/8" 7-5/8" 3-7/8"...
Page 57
APPENDIX F Insulation material installation diagrams VISION 24 x 120 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST Qty: 2 Qty: 1 Qty: 2 4-1/2" 4-3/4" 7" TOP VIEW 4-1/2" 6-5/8"...
Page 58
APPENDIX F Insulation material installation diagrams VISION 24 x 120 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 24 X 120 INCH EVAPORATOR Product code: IB016-241000ST REAR RISER WEDGE Qty: 1 See note opposite* 2" 21" FRONT VIEW TOP VIEW REAR INNER SIDE FACES...
ANNEXE G INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 30 X 120 IN. INSULATION PANEL INSTALLATION DIAGRAMS FOR SIDES 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST Qty: 4 Qty: 2 12" 6-1/8" 21-3/4" 21-3/4" Qty: 2 Qty: 2 12" 12" 14-1/4"...
Page 60
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR INTERIOR FRONT VIEW 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST Qty: 2 Qty: 1 REAR VIEW 20-1/4" 32" 17-3/4" 4" 31-3/8" 5-5/8"...
Page 61
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR FLOOR RISER 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST Qty: 1 Qty: 1 12" 12" 21-1/4" 23" 23" 24-5/8" TOP VIEW Qty: 1...
Page 62
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) INSULATION PANEL CUTTING PATTERNS 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST Qty: 4 Qty: 2 Qty: 2 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 63
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST Qty: 14 Qty: 2 Qty: 16 4-1/2" 4-1/2" 4-1/2" 7-3/8" 7-5/8" 3-1/2"...
Page 64
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST TOP VIEW Qty: 2 Qty: 5 Qty: 2 Qty: 2 FRONT VIEW 4-1/4"...
Page 65
APPENDIX G Insulation material installation diagrams VISION 30 x 120 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 30 X 120 INCH EVAPORATOR Product code: IB016-301000ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10" 74" REAR WALL Qty: 1 10" *NOTE: One-inch thick wedge made of mat or 31"...
APPENDIX H INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 36 X 120 IN. INSULATION PANEL INSTALLATION DIAGRAMS FOR SIDES 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST Qty: 4 Qty: 2 12" 6-1/8" 21-3/4" 21-3/4" Qty: 2 Qty: 2 12" 12" 14-1/4"...
Page 67
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR INTERIOR FRONT VIEW 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST Qty: 1 Qty: 2 REAR VIEW 20" 36" 18-1/4" 4" 34-1/4" 5-1/8"...
Page 68
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR FLOOR RISER 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST Qty: 1 Qty: 1 12" 12" 29" 30" 27-1/2" 29" TOP VIEW Qty: 1 Qty: 1 6-5/8"...
Page 69
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) INSULATION PANEL CUTTING PATTERNS 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST Qty: 2 Qty: 4 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 70
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST Qty: 14 Qty: 2 Qty: 16 4-1/2" 4-1/2" 4-1/2" 7-3/8" 3-7/8" 7-5/8"...
Page 71
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST TOP VIEW FRONT VIEW Qty: 5 Qty: 2 Qty: 2 Qty: 2 3"...
Page 72
APPENDIX H Insulation material installation diagrams VISION 36 x 120 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 36 X 120 INCH EVAPORATOR Product code: IB016-361000ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10" 74" REAR WALL Qty: 1 *NOTE: One-inch thick 10"...
APPENDIX I INSULATION MATERIAL INSTALLATION DIAGRAMS VISION 36 X 144 IN. INSULATION PANEL INSTALLATION DIAGRAMS FOR SIDES 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST Qty: 4 Qty: 2 12" 11-1/8" 21-3/4" 21-3/4" Qty: 2 Qty: 2 12" 12" REAR VIEW 15-3/4"...
Page 74
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR INTERIOR FRONT VIEW 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST Qty: 2 Qty: 1 REAR VIEW 36" 20" 18-1/4" 34-1/4" 4" 5-1/8"...
Page 75
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) INSULATION PANEL INSTALLATION DIAGRAMS FOR FLOOR RISER 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST Qty: 1 Qty: 1 12" 12" 29" 27-1/2" 29" 30" TOP VIEW Qty: 1 Qty: 1 12"...
Page 76
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) INSULATION PANEL CUTTING PATTERNS 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST Qty: 2 Qty: 2 Qty: 2 Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 77
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) INSTALLATION DIAGRAMS FOR HIGH-TEMPERATURE BRICK ON THE SIDES 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST Qty: 14 Qty: 2 Qty: 20 4-1/2" 4-1/2" 4-1/2" 2" 3-7/8" 3-7/8"...
Page 78
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) HIGH-TEMPERATURE BRICK INSTALLATION DIAGRAMS FOR FLOOR RISER 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST TOP VIEW FRONT VIEW Qty: 5 Qty: 2 Qty: 2 Qty: 2 4"...
Page 79
APPENDIX I Insulation material installation diagrams VISION 36 x 144 in. (continued) INSULATING MAT INSTALLATION DIAGRAM 36 X 144 INCH EVAPORATOR Product code: IB016-361200ST REAR INNER SIDE FACES Qty: 2 FRONT VIEW 10" 86" REAR WALL Qty: 1 *NOTE: One-inch thick 10"...
- If you are using a rope operated rain cap, install the actuator cables from the cap. • Following the installation of this final chimney assembly, check and adjust its alignment with the part under the roof, then tighten the guide wires. Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
Page 81
Section with lugs, for receiving steel guide cables Flashing rain tie, or pipe and flashing collar Single section, typical 4 ft. (1.22 m) pipe Chimney connector, installed on the evaporator Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
- If you are using a rope operated rain cap, install the actuator cables from the cap. • Check and adjust the alignment of the steam vent with the part under the roof. Lapierre Equipment | | USER MANUAL | Version 03 - March 2023...
Page 83
Single section, typical 4 ft. (1.22 m) pipe Steam vent rain cap (Illustrated: rope operated rain cap) Flashing rain tie, or pipe and flashing collar Hood pipe collar, sliding Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...
ANNEXE L VISION PERFORMANCE PERFORMANCE EXCEPTIONAL VISION PERFORMANCE * Evaporation in gallons of water/hr DIMENSIONS RANGE GALLONS US/HR 18" 48” Hobby 18" 48” Single Pan 18" 48” Standard 18" 60” Single Pan 18" 60” Standard 24" 72” Accordion Pleats/Folds 24"...
Page 85
• If you move the back pleated pan, be sure to replace the • Depending on the size and VISION model, various boiling wool on the deflector, if necessary. distributions can be found in the back pleated pan, without affecting its performance.
Page 86
NOTES Lapierre Equipment | | USER MANUAL | Version 03 - March 2023 VISION EVAPORATOR...