Advertisement

Quick Links

INSTALLATION AND
OPERATING
INSTRUCTIONS
Unit, electro-pneumatic
AEPN1100-00-A
DDOC01693
THE KNOW-HOW FACTORY
www.zimmer-group.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEPN1100-00-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zimmer AEPN1100-00-A

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS Unit, electro-pneumatic AEPN1100-00-A DDOC01693 THE KNOW-HOW FACTORY www.zimmer-group.com...
  • Page 3: Table Of Contents

    11.1 Checking operational readiness .......................................14 12 Maintenance ....................................15 13 Decommissioning/disposal ..............................15 14 RoHS declaration ..................................16 15 Declaration of Conformity ................................. 17 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 4: Supporting Documents

    General notices contain usage tips and valuable information, but no warnings of dangers to health. INFORMATION This category contains useful tips for handling the product efficiently. Failure to observe these tips will not result in damage to the product. This information does not include any information relevant to health or workplace safety. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 5: Safety Notices

    The product is not suited to generate negative pressure. Observance of the technical data and of the installation and operating instructions are part of proper use. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 6: Personnel Qualification

    The runtime limitation and the temperature sensors switch the product off in case of overload to prevent the product from overheating. Various statuses as well as the available system pressure can be read via pins 7 and 8. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 7: Led Status Display

    • Motor operating time > 83 h ► Please contact Zimmer + 24 V DC Customer Service. Error Continuous light • Undervoltage ► Check the supply voltage. + 24 V DC Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 8: Technical Data

    8 Accessories/scope of delivery INFORMATION If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products. ► For optional accessories and those included in the scope of delivery, refer to our website.
  • Page 9: Installation

    ► Installation may only be carried out by qualified personnel in accordance with these installation and operating instructions. ► Switch off the power supply before any assembly, installation or maintenance work. ► Install the product on an appropriate mounting surface in accordance with the flatness specifications. ► Make sure that the mounting piece is sufficiently rigid. ► Verify the permitted load capacity of the required screw connections in accordance with VDI 2230. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 10: Installing The Product

    • With the wall mounting brackets downwards ► Mount the product using the mounting screws. Mounting screw Front cover Wall mounting bracket Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 11: Installing The Energy Supply

    P2 pneumatic connection. ► Keep the hose length as short as possible for a quick air supply and bleeding. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 12: Setting The Pressure Range

    ► Connect the product according to its assignment diagram. Electrical connection Controller I4 I5 I6 I7 I8 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 13 • + 24 V DC: Warning or error 8-pin plug Molex 395040008 Cable size AWG 16, 18, 20, 22, 24, 26, 28, 30 Cable size [mm 0.05–1.31 Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 14: Commissioning

    ► Check to ensure that there is no warning or fault signal. ► Check whether the LED lights up green and the product is ready for operation. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 15: Maintenance

    ► Dispose of the components properly according to the material groups. ► Comply with the locally applicable environmental and disposal regulations. Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...
  • Page 16: Rohs Declaration

    Authorized representative for the (Place and date of issuance) Martin Zimmer compilation of relevant technical (Legally binding signature) documents Managing Partner Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com...