6.6

Filters maintenance

If the dust collector loses suction power, do the steps as follow:
1. Do a check of all dust hoses and connections for damages and obstructions.
2. Make sure that the Longopack bags are empty.
3. Make sure that the compressor is fully pressurized and set it to off.
4. Remove all moisture from the main air tank with the drain valve.
5. Turn on the compressor until it is fully pressurized again, now remove all moisture from the pulse air
tank with its drain valve.
6. Turn on the compressor until it is fully pressurized again, now use the air gun to completely empty the
pulse tank.
7. Only turn on the compressor and keep the fan unit turned off. Close the butterfly valves of the pre-
separator and dust collector. Make sure that there are Longopack bags underneath the dust collector
and pre-separator. Let the machine pulse for about a half an hour to clean the filters from the inside.
When the magnesense meter indicate more than 1.9 kPa (20 cm H
fitted properly inside the filter chamber.
1. Do a check if the filters are damaged or installed incorrectly.
2. Replace the filter.
3. Clean thoroughly the compartment above the filters and the connection of the air hoses.
Do not continue the work with a damaged filter or if there is a leakage. It can cause serious damage to the
machine and is a health hazard!
Never expose the filter cartridges to moisture!
21.07.2023
Observe the pressure difference gauge.
When the pressure difference gauge is above 1.9 kPa
(20 cm H
CUW Cartridge Filter
IFA/BIA certificate M-class
Order nr. E10600
O), the filters are probably clogged.