58
R E P A I R S

7.7 Flowmeter

Before changing the Flowmeter repairing operations 7.3.2, 7.3.4 and 7.3.5 has to be
completed.
1. Raise the flowmeter and remove the
hoses that connect to the water tank
connector and to the pump.
2. Remove the flowmeter.
Service manual ZN100 V 6.0
To the watertank
connector.
To the pump.