T R O U B L E S H O O T I N G

6.3 Coffee capsule falls through

An inserted new coffee capsule falls through the brewing unit into the
capsule container immediately.
Possible reasons:
The used capsule has a deformed border.
A used capsule is stucked into the extraction chamber.
The limit stop or the ejector in the extraction unit is stucked or damaged.
Remedy:
Try again using a new capsule (without deformation).
Check for stucked capsule in extraction unit (use a spoon to remove it).
Check ejection mechanism.
Replace complete extraction unit if defective.

6.4 Only hot water during coffee preparation

The used coffee capsule is not or only partly perforated on both sides.
Possible reasons:
A second capsule is stucked in the brewing chamber of the extraction unit.
The capsule is not well positioned in the brewing chamber.
A deformed capsule border - the hot water flows straight to the coffee outlet.
Remedy:
Check for stucked capsule(s) in extraction unit.
Try again using a new capsule (without deformation).

6.5 Wrong water empty signal

Water empty signal, but the water tank is full.
Possible reasons:
Floater in water tank stucked.
Water sensor defective.
Exchange of the back panel (incl. water level PCBA).
Remedy:
Clean floater chamber in water tank.
Replace water sensor.
Calibrate water sensor.
Service manual ZN100 V 6.0