General Ratings
Conform to C-series ratings.
Characteristics
Common Characteristics
Communication
Synchronization
Transmission lines
Interface
Transmission speed
Transmission distance
C500 Remote I/O Master Unit (C500-RM201)
Power consumption
Weight
Diagnostic functions
C500 Remote I/O Slave Unit (C500-RT201)
Power consumption
Weight
RUN Output
Diagnostic functions
C200H Remote I/O Master Unit (C200H-RM201)
Power consumption
Weight
Diagnostic functions
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Appendix B
Specifications
Two-line, half-duplex
Start-stop
2-conductor (VCTF 0.75 mm recommended.)
RS-485
187.5 kbps
200 m (total length per Master)
300 mA max. at 5 V
500 g max.
Transmission error checks
BCC and reversed transmission verification
CPU Unit error monitoring
Transmission line short check
500 mA max. at 5 V
500 g max.
OMRON G6B relay (closed during operation)
Contact capacity: 2 A max. at 250 VAC or 24 VDC (cos
Transmission error checks
BCC and reversed transmission verification
CPU Unit error monitoring
200 mA max. at 5 V
350 g max.
Transmission error checks
CPU Unit error monitoring
Transmission line short check
φ
= 1)