Modular Type - SMC Networks PF3AmH Series Manual

Digital flow switch for large flow
Table of Contents

Advertisement

PF3A
7
Integrated display
Symbol Rated flow range Applicable air combination model
01
10 to 1000 L/min
02
20 to 2000 L/min
FUNC ∗
Symbol OUT
NPN Analog voltage output ∗
CS
NPN Analog current output ⇔ External input ∗
DS
PNP Analog voltage output ∗
ES
PNP Analog current output ⇔ External input ∗
FS
∗1 Analog output or external input can be selected by pressing the buttons.
Analog output is set as default setting.
∗2 1 to 5 V or 0 to 10 V can be selected by pressing the button. The
default setting is 1 to 5 V.
∗3 The accumulated value, peak value, and bottom value can be reset.
Options/Part Nos.
When only optional parts are required, order with the part numbers listed below.
Part no.
Option
ZS-37-A
Lead wire with M12 connector
ZS-49-A
Lead wire with M12-M12 connector Male/female conversion, Length: 3 m
Pipe threads are not provided for this product. If the product is to be used as a single unit, order a spacer (or spacer with bracket) and a
piping adapter separately. Refer to page 30 for details on attachments.
Assembly Example
∗ Avoid mounting the lubricator on the inlet side.
∗ If a pressure relief 3-port valve is installed on the inlet side of the digital
flow switch, causing a backflow of air, the measured value will change.
17
A

Modular Type

3-Color Display
PF3A7  H
7
01
H
Type
Rated flow range
AC30-D
AC40-D
Large flow type
Output specification
1
Applicable monitor unit model
⇔ External input ∗
2
3
PFG300 series
3
PFG310 series
⇔ External input ∗
2
3
PFG300 series
3
PFG310 series
Note
Length: 3 m
Caution on Mounting
e Spacer with bracket
r Piping adapter
q Digital flow switch
w Air combination
Digital Flow Switch
How to Order
CS
M
Calibration certificate
∗8 The certificate is in both English and Japanese.
∗9 Made to order
Unit specification
Nil
M
∗6 This product is for overseas use only. (The SI unit type is
provided for use in Japan in accordance with the New
Measurement Act.)
∗7 Fixed units: Instantaneous flow: L/min
Option
4
Nil
With lead wire with connector (3 m)
N
Without lead wire with connector
Lead wire with M12-M12 connector (3 m) ∗
Q
∗4 Options are shipped together with the product but
do not come assembled.
∗5 The lead wire has an M12 (female) connector on
one side and an M12 (male) connector on the
other side.
Assembly example
q Digital flow switch PF3A701H-CS-M
w Air combination AC30B-03E-D
e Spacer with bracket Y300T-D
r Piping adapter E300-03-D
Products do not come assembled. They should be ordered
separately and assembled by the customer.
Series
Flow direction
Nil
Left to right
R
Right to left
8
Nil
None
A
9
Yes
Units selection function ∗
6
SI units only ∗
7
Accumulated flow: L
5
Simple Specials System
A system designed to respond quickly and easily
to your special ordering needs
Please contact your local sales representative for more
details.
RoHS
1 pc.
1 pc.
2 pcs.
1 pc.

Advertisement