Download Print this page

SMC Networks PFA Series Quick Start Manual

Digital flow switch
Hide thumbs Also See for PFA Series:

Advertisement

Quick Links

Remote Type
Sensor Unit
Flow rate range
10
1 to 10
50
5 to 50
11
10 to 100
21
20 to 200
51
50 to 500
Specifications
Model
Measured fluid
Detection type
Flow rate measurement range
Operating pressure range
Proof pressure
Pressure loss
Operating temperature range
Note 1)
Linearity
Repeatability
Temperature
characteristics
Power supply voltage
Current consumption
Weight
Enclosure
Port size (Rc, NPT, G)
Note 1) The system accuracy will be adjusted to ±5% F.S. or less when combined with PFA3
Note 2) The system accuracy will be adjusted to ±1% F.S. or less when combined with PFA30 .
∗ Flow rate unit measured under the following conditions: 0°C and 101.3kPa.
PFA5
10
/min
l
l
/min
l
/min
Thread type
l
/min
l
/min
Nil
Rc
N
NPT
F
G
PFA510
PFA550
1 to 10
/min
5 to 50
l
3kPa (at 50
l
/min)
±25% F.S. or less
±1% F.S. or less
Note 2)
200g (without lead wire)
1/8, 1/4
Digital Flow Switch
How to Order
01
Wiring specification
Nil
3m lead wire with connector
N
Without lead wire
Port size
Flow rate (
Port
Symbol
size
10
50
100
b
b
01
1/8
b
b
02
1/4
03
3/8
04
1/2
PFA511
Dry air, N
2
Heater type
/min
10 to 100
l
/min
l
0 to 0.5MPa
1.0MPa
3kPa (at 100
l
/min)
0° to 50°C (with no condensation)
±2% F.S. or less (15° to 35°C)
±3% F.S. or less (0° to 50°C)
12 to 24VDC (ripple ±10% or less)
100mA or less
IP65
.
For Air
Series
l
/min)
Applicable models
200
500
PFA510, PFA550
b
b
PFA511, PFA521
b
PFA551
PFA521
20 to 200
l
/min
10kPa (at 200
l
/min)
±20% F.S. or less
±1% F.S. or less
240g (without lead wire)
3/8
PFA
PFA551
50 to 500
l
/min
30kPa (at 500
/min)
l
110mA or less
1/2
3

Advertisement

loading
Need help?

Need help?

Do you have a question about the PFA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PFA Series

  • Page 1 For Air Series Digital Flow Switch How to Order Remote Type PFA5 Sensor Unit Wiring specification Flow rate range 3m lead wire with connector 1 to 10 /min Without lead wire 5 to 50 /min Port size 10 to 100 /min Thread type 20 to 200...
  • Page 2: Error Correction

    Series Sensor Unit Construction PFA710, PFA750 PFA510, PFA550 Parts list Description Material Attachment Seal Mesh Stainless steel Body Sensor Flow direction PFA711, PFA721, PFA751 PFA511, PFA521, PFA551 Parts list Material Description Attachment Seal Spacer Stainless steel Mesh Body Sensor Flow direction Operating Unit Descriptions LED Display RESET Buttons...
  • Page 3 For Air Series Digital Flow Switch Flow Rate Setting Setting procedure Key lock Manual flow mode rate setting Even if button is pressed Set the flow rate that during operation, mode performs switch output. will not be switched. Initial setting Initial setting: Sets the display mode (real-time flow rate/accumulated...
  • Page 4 Series Flow Rate Setting Flow rate setting mode (manual) Set Value Input Manual Mode Setting the first (1) Mode (Manual) Value for OUT 1 Setting Press the SET button. OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Press the SET button. Press the SET button when Set the first (1) value for OUT1.
  • Page 5: Other Functions

    For Air Series Digital Flow Switch Other functions Accumulated flow function Key lock mode • • Prevents incorrect operations of the button control. Start of Start of Accumulation Key Lock Function OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Press the SET button to complete Start accumulation.
  • Page 6 For Air Series Digital Flow Switch Remote Type Sensor Unit for Air Dimensions: PFA510, PFA550 Wiring Brown (1) DC(+) 48.2 Black (4) OUT Blue (3) DC(–) ∗ Use this sensor by connecting to SMC remote type display unit Series PFA3 (1), (3), and (4) are connector pin numbers.

This manual is also suitable for:

Pfa510Pfa550Pfa511Pfa521Pfa551