Digital flow switch for large flow
Table of Contents

Advertisement

Specifications
Model
Applicable fluid *
Fluid
Fluid temperature
Detection method
Rated flow range
Set point range *
Flow
Smallest settable
increment
Accumulated volume per pulse
(Pulse width = 50 ms)
Accumulated value hold function *
Rated pressure range
Proof pressure
Pressure
Pressure loss
Pressure characteristics *
Power supply voltage
Electrical
Current consumption
Protection
Display accuracy
Analog output accuracy
Accuracy
Repeatability
Temperature characteristics
Output type
Output mode
Switch operation
Max. load current
Switch output
Max. applied voltage (NPN only)
Internal voltage drop
(Residual voltage)
Response time *
Hysteresis *
6
Protection
Output type
Analog output *
7
Impedance
Response time *
Input type
External input *
10
Input mode
Input time
Reference condition *
Unit *
12
Display range *
Display
Minimum
display unit
Display
Indicator LED
Enclosure
Withstand voltage
Environmental
Insulation resistance
resistance
Operating temperature range
Operating humidity range
Standards
Piping
Piping specification
Main materials of parts in contact with fluid
Length of lead wire with connector
Piping
Weight
specification
Lead wire with connector
*1 Air quality grade is JIS B 8392-1:2012 [4:6:-] and ISO 8573-1:2010 [4:6:-].
*2 Set point range will change according to the setting of the zero cut-off function.
*3 When using the accumulated value hold function, use the operating conditions to calculate
the product life, and do not exceed it. The maximum update limit of the memory device is 1.5
million times. If the product is operated 24 hours per day, the product life will be as follows:
· 5 min interval: life is calculated as 5 min x 1.5 million = 7.5 million min = 14.3 years
· 2 min interval: life is calculated as 2 min x 1.5 million = 3 million min = 5.7 years
If the accumulated value external reset is repeatedly used, the product life
will be shorter than the calculated life.
*4 When the pressure range is 1.0 to 1.5 MPa, the pressure characteristics will be ±5% F.S.
(standard pressure is 0.5 MPa). Do not release the OUT side piping port of the product to
the atmosphere without connecting piping. If the product is used with the piping port re-
leased to atmosphere, accuracy may vary.
*5 The time from when the flow is changed by a step input (when the flow rate
changes from 0 to the maximum value of the rated flow range instantaneously)
until the switch output turns ON (or OFF) when set to be 90% of the rated flow rate
3-Color Display
PF3A703H
1
30 to 3000 L/min
Instantaneous flow
30 to 3150 L/min
2
Accumulated flow
0 to 999,999,999,990 L
Instantaneous flow
2 L/min
Accumulated flow
10 L
3
4
Select from Instantaneous output (Hysteresis mode or Window comparator mode), Accumulated output, or Accumulated pulse output.
5
Voltage output: 1 to 5 V (0 to 10 V can be selected *
Voltage output
Current output
9
Select from Accumulated value external reset or Peak/Bottom value reset.
11
Instantaneous flow
Accumulated flow
0 to 3150 L/min
Instantaneous flow
13
(Flow under 30 L/min is displayed as "0")
Accumulated flow *
14
0 to 999,999,999,990 L
Instantaneous flow
2 L/min
Accumulated flow
10 L
50 MΩ (500 VDC measured via megohmmeter) between terminals and housing
Operating: 0 to 50°C, Stored: −10 to 60°C (No freezing or condensation)
Rc1, NPT1, G1
Aluminum alloy, PPS, HNBR [Sensor: Pt, Au, Fe, Lead glass (exempted from the RoHS application), Al
Rc
610 g
NPT
610 g
G
630 g

Body Ported Type

Digital Flow Switch
For flow switch precautions and specific product precautions,
refer to the "Operation Manual" on the SMC website.
PF3A706H
Air, Nitrogen
0 to 50°C
Thermal type
60 to 6000 L/min
60 to 6300 L/min
5 L/min
Select from 100 L/pulse or 1000 L/pulse.
Intervals of 2 or 5 minutes can be selected.
0.1 to 1.5 MPa
2.25 MPa
Refer to the "Pressure Loss" graph on page 24.
±2.5% F.S. (0.1 to 1.0 MPa, 0.5 MPa standard)
24 VDC ±10%
150 mA or less
Polarity protection
±3.0% F.S.
±3.0% F.S.
Switch output/Display: ±1.0% F.S.
Analog output: ±1.0% F.S.
±5.0% F.S. (Ambient temperature of 0 to 50°C, 25°C standard)
NPN open collector
PNP open collector
Select from Normal or Reversed output.
80 mA
28 VDC
NPN output type: 1 V or less (at load current of 80 mA)
PNP output type: 2 V or less (at load current of 80 mA)
Select from 1 s, 2 s, or 5 s.
Variable from 0
Over current protection
Output impedance: Approx. 1 kΩ
Maximum load impedance: Approx. 600 Ω
Linked to the response time of the switch output
No-voltage input: 0.4 V or less
30 ms or longer
Select from Standard conditions or Normal conditions.
L/min, CFM (ft
L, ft
3
0 to 6300 L/min
(Flow under 60 L/min is displayed as "0")
5 L/min
LCD, 2-screen display (Main screen/Sub screen)
Main screen: Red/Green, Sub screen: Orange
Main screen: 5 digits, 7 segment, Sub screen: 6 digits, 7 segment
OUT indicator: Red LED is ON when output is ON
IP65
1000 VAC for 1 minute between terminals and housing
Operating/Stored: 35 to 85% RH (No condensation)
CE/UKCA marking
Rc1 1/2, NPT1 1/2, G1 1/2
3 m
1190 g
1190 g
1220 g
+90 g
*6 If the flow fluctuates around the set value, the width for setting more than
the fluctuating width needs to be set. Otherwise, chattering will occur.
*7 Analog output or external input can be selected by pressing the buttons.
Refer to the graph for analog output.
*8 When selecting 0 to 10 V, refer to the analog output graph for the allowable load current.
*9 The time from when the flow is changed by a step input (when the flow rate
changes from 0 to the maximum value of the rated flow range instantane-
ously) until the analog output reaches 90% of the rated flow rate
*10 Analog output or external input can be selected by pressing the buttons.
*11 The flow rate given in the specifications is the value under standard conditions.
*12 Setting is only possible for models with the units selection function.
*13 Display range will change according to the setting of the zero cut-off function.
*14 The accumulated flow display is the upper 6-digit and lower 6-digit (total of
12 digits) display. When the upper digits are displayed, x 10
* Products with tiny scratches, marks, or display color or brightness variations which
do not affect the performance of the product are verified as conforming products.
PF3A7 mH
PF3A712H
120 to 12000 L/min
120 to 12600 L/min
0 to 999,999,999,900 L
10 L/min
100 L
8
), Current output: 4 to 20 mA
3

/min)

0 to 12600 L/min
(Flow under 120 L/min is displayed as "0")
0 to 999,999,999,900 L
10 L/min
100 L
Rc2, NPT2, G2
1680 g
1680 g
1720 g
Series
O
]
2
3
lights up.
6
14
A