Internal Components; Components Description - SystemAir SAVE VTC 200-1 Service & Accessories Installation Manual

Hide thumbs Also See for SAVE VTC 200-1:
Table of Contents

Advertisement

24
| Service
4.3

Internal components

Position
Description
1
Fan, supply air
2
Fan, extract air
3
Filter, outdoor air
4
Filter, extract air
5
Temperature sensor, supply air
6
Temperature sensor, outdoor air
7
Relative humidity/Extract air temperature sensor
8
Print card with terminals
9
Heat exchanger
10
External connections
11
Defrost damper
1
The damper may not be turned by hand!
4.3.1

Components description

4.3.1.1 Fans
Fans have an external EC type rotor which can be steplessly controlled individually 16–100%. The motor bearings are
life time lubricated and maintenance free. It is possible to remove the fans for cleaning, see "User Manual" for more
information.
4.3.1.2 Filters
The air filter captures dust, mold, pollen and other particulate matter.
The filters need to be replaced when polluted. New sets of filters can be acquired from your installer or wholesaler.
4.3.1.3 Heat exchanger
SAVE VTC 200 – 1is equipped with a counter flow heat exchanger. Required supply air temperature is therefore nor-
mally maintained without adding additional heat.
4.3.1.4 Main circuit board
The main circuit board controls all functions and the unit.