Toro 31527 Installation Instructions Manual page 8

Groundsmaster 4500-d or 4700-d traction unit flow divider kit
Table of Contents

Advertisement

Figure 8
1. Flow-divider manifold
2. Pressure hose (divider
fitting)
3. Rear-traction tube
(forward fitting)
3.
Remove the temporary cap from the hydraulic
pump.
4.
Thread one straight end of the pressure hose
into the fitting in the hydraulic pump
5.
Remove the temporary cap from the flow-divider
manifold.
6.
Thread the other straight end of the pressure
hose into the fitting in the side of the flow-divider
manifold
(Figure
8).
7.
Tighten the hose fittings to 150 to 184 N∙m (110
to 136 ft-lb).
g205014
4. Pressure hose (pump
fitting)
5. Hydraulic pump
6. Forward
(Figure
8).
Installing the Cross Tube
1.
Remove the cap on the fitting of the rear-traction
manifold that you previously installed.
2.
Align the tube nuts for the cross-manifold tube to
the fittings in the rear-traction manifold and the
flow-divider manifold
1. Rear-traction manifold
2. Cross-manifold tube
(rear-traction manifold
fitting)
3. Cross-manifold tube
(divider fitting)
3.
Thread the tube nuts onto the fittings in the
flow-divider manifold and the rear-traction
manifold, and tighten the nuts to 51 to 63 N∙m
(37 to 47 ft-lb).
8
(Figure
9).
Figure 9
4. Flow-divider manifold
5. Forward
g205016

Advertisement

Table of Contents
loading

Table of Contents