Toro 31527 Installation Instructions Manual page 16

Groundsmaster 4500-d or 4700-d traction unit flow divider kit
Table of Contents

Advertisement

1. Relay
2. Relay connector
9.
Route the 2 remaining wires that are not directly
attached to the relay halfway along the existing
wire harness under the frame until directly above
the 3-way manifold
1. Wire harness leading
down to flow-divider
manifold
2. Wire harness routed along
frame
10.
Unplug the coil from the 3-way manifold
29).
Figure 27
3. Wire harness continuing
down to flow-divider
manifold
(Figure
28).
Figure 28
3. Wire harness ends at
3-way manifold
4. 3-way manifold location
beneath lower frame
g205034
1. Coil from existing wire
harness
2. Connection 3-way
manifold
11.
Connect the plug you just removed into the free
socket on the new wire harness
g205054
1. Free socket
12.
Connect the angled plug from the new wire
harness into the coil on the 3-way manifold
Figure
(Figure
16
Figure 29
Bottom View
3. 3-way manifold
4. Front of machine
Figure 30
Bottom View
2. Existing plug
31.
g205037
(Figure
30).
g205039