Toro 31527 Installation Instructions Manual page 6

Groundsmaster 4500-d or 4700-d traction unit flow divider kit
Table of Contents

Advertisement

3
Installing the Coils on
the Flow-Divider Manifold
Assembly
4WD Switch Only
Parts needed for this procedure:
1
Plug
2
Valve
2
Coil (12 V)
2
Coil nut
Procedure
Important:
The manifold comes pre-assembled
for use without the switch; this procedure is
necessary if you install the 4WD switch.
1.
Remove the 2 existing valves from the CV1 and
CV2 ports of the manifold.
2.
Install the appropriate parts to the flow-divider
manifold as shown in
Figure
5.
1. Coil nut
2. Coil (12 V)
3. Valve
3.
Torque the coil nuts to 6.8 to 9.5 N∙m (5 to 7
ft-lb).
4.
Torque the valves to 34 N∙m (25 ft-lb).
5.
Install the plug over the new orifice.
Note:
You may discard the removed orifice and
valves.
6
Figure 5
4. Existing orifice (removed)
5. Plug
6. New orifice
g230515

Advertisement