Temperature Sensor Area; Cooking Chamber Sensor Defective (694, 695) - Henny Penny FSHN610 Service Instructions Manual

Table of Contents

Advertisement

Fault messages & troubleshooting

11.3 Temperature sensor area

Cooking chamber sensor defective (694, 695)

Check contacting from cooking chamber sensor to control board A1 X31. Error eliminated?
Remove existing cooking chamber sensor from the control board A1 X31 and plug in new cooking
Replace control board.
52
Description
Emergency operation is activated automatically and displayed. The
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
Troubleshooting
chamber sensor. Error eliminated?
No
Service-instructions
Yes
Replace cooking chamber sensor.

Advertisement

Table of Contents
loading

Table of Contents