Fault messages & troubleshooting
Water vapor sensor defective (710)
Check contacting from cooking chamber sensor to control board A1 X33. Error eliminated?
Remove connector of existing vapor sensor from control board A1 X33 and plug in new vapor
Replace control board.
54
Description
In the event of an error, emergency operation is activated and
displayed automatically. The software controls steam elimination. In
this case, increased water consumption may result.
Troubleshooting
sensor. Error eliminated?
No
Service-instructions
Yes
Replace vapor sensor.