Air cooled chiller with inverter driven screw compressor (53 pages)
Summary of Contents for Daikin EWAA006D2V3P
Page 1
Operation manual Packaged air-cooled water chillers and packaged air to water heat pumps EWAA004D2V3P EWAA006D2V3P EWAA008D2V3P EWYA004D2V3P Operation manual EWYA006D2V3P Packaged air-cooled water chillers English EWYA008D2V3P and packaged air to water heat pumps...
Latest revisions of the supplied documentation may be available on 5.8.4 Using weather-dependent curves ....... 15 the regional Daikin website or via your installer. 6 Energy saving tips The original documentation is written in English. All other languages 7 Maintenance and service are translations.
2 User safety instructions 1 Starting from the home screen, turn the left dial and CAUTION go to Space heating/cooling. ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the Space heating/cooling unit.
3 About the system ▪ Do NOT use cleaning materials or Components in a typical system layout means to accelerate the defrosting process other than those recommended by the manufacturer. ▪ Be aware that the refrigerant inside the system is odourless. WARNING ▪...
4 Quick guide 2 Adjust the desired room temperature. Advanced user 1234 °C – Room Space heating/cooling a Actual room temperature To turn room temperature control ON or OFF b Desired room temperature 1 Go to [C.1]: Operation > Room. Operation To change the desired leaving water temperature You can use the leaving water temperature setpoint screen to read...
5 Operation There are 2 types of WD curves: slope-offset curve (default), and 2-points curve. If needed, you can change the type in [2.E] Main zone > WD curve type. The way to adjust the curve depends on the type. Slope-offset curve Slope.
Page 7
5 Operation Item Description d Help button : Press to show a help text related to the current page (if available). e Right dial The LCD shows an arc on the right side of the display when you can use the right dial. ▪...
5 Operation Menu structure: Overview user settings INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Room Schedule Heating schedule Cooling schedule Antifrost [1.4] Antifrost Setpoint range Room sensor offset Activation Room comfort setpoint Room setpoint [1.5] Setpoint range Heating minimum...
5 Operation Possible screens: Overview Item Description c Smart energy The most common screens are as follows: Smart energy is available via solar panels or smart grid. Smart energy is currently being used for space heating. d Space operation mode Cooling Heating e Outdoor / quiet mode...
5 Operation Examples Malfunctioning [1] Room temperature screen [2] Main zone screen Room Main zone Additional zone Space heating/cooling °C °C – – Selected submenu Room Main zone Possible actions on this screen Go through the list. [3] Additional zone screen Enter the submenu.
5 Operation 1 Go to [C.2]: Operation > Space heating/cooling. Turning operation ON or OFF Operation 5.4.1 Visual indication Room Space heating/cooling Certain functionalities of the unit can be enabled or disabled separately. If a functionality is disabled, the corresponding temperature icon in the home screen will be greyed out.
5 Operation To turn off room temperature scheduling To tell the system which space operation to use, you can: 1 Go to [1.1]: Room > Schedule. You can… Location 2 Select No. Check which space operation mode is Home screen currently used.
Page 13
5 Operation To program the schedule for Monday User defined 1 1 Select Monday. User defined 1 Prerequisite: The room temperature schedule is only available if room thermostat control is active. If leaving water temperature control is active, you can program the main zone schedule instead. 2 Select Edit.
5 Operation 4 Select Paste. 2 Select Rename. Delete Edit Delete Copy Rename Paste Select 3 (optional) To delete the current schedule name, Result: browse through the character list until ← is User defined 1 displayed, then press to remove the previous character.
5 Operation 5.8.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example Weather-dependent curve when offset is selected: Item Description Selected weather dependent zone: ▪ : Main zone or additional zone heating ▪...
6 Energy saving tips Go to setpoint mode … Set the setpoint mode to … You feel … Fine-tune with setpoints: [2.4] Main zone > Setpoint WD heating, fixed cooling mode OR Weather dependent At regular outdoor At cold outdoor temperatures …...
8 Troubleshooting NOTICE 1 Press the left dial to open the main menu and go to Malfunctioning. Applicable legislation on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated Result: A short description of the error and the error both in weight and CO equivalent.
9 Disposal Possible cause Corrective action Installer settings: Tables to be Unit is damaged. "8.1 To display the help text filled in by installer malfunction" [ 4 17]. in case of a INFORMATION 10.1 Configuration wizard When the backup heater takes over the heat load, electricity consumption will be considerably higher.
Page 20
4P688015-1 0000000Q 4P688015-1 2022.04 Verantwortung für Energie und Umwelt...
Need help?
Do you have a question about the EWAA006D2V3P and is the answer not in the manual?
Questions and answers