press the function button +, the most recent individual meas-
ured values are displayed in turn with the date and time.
• To switch off, press the START/STOP button
• If you forget to switch off the device, it will switch itself off
automatically after 30 seconds.
• If you want to delete the whole memory for a specific user,
press the memory button M. Press and hold down the
memory button M and the setting button SET simultaneously
for 5 seconds.

8. Error messages/troubleshooting

In the event of errors, the error message _ appears on the
screen.
Error messages may appear if:
• It was not possible to correctly record the pulse:
• No measurement could be taken:
• The cuff is fastened too tightly or loosely:
• Errors occur during the measurement:
• The pump pressure is higher than 300 mmHg:
• There is a system error. If this error message appears, please
contact Customer Services:
• The batteries are almost empty:
In such cases, repeat the measurement. Ensure that the cuff
line is correctly attached and that you do not move or speak
during the measurement. If necessary, reinsert or replace the
batteries.

9. Cleaning and storing the device and cuff

• Clean the device and cuff carefully using a slightly damp
cloth only.
.
;
;
;
;
;
.
.
• Do not use any cleaning agents or solvents.
• Under no circumstances hold the device and cuff under wa-
ter, as this can cause liquid to enter and damage the device
and cuff.
• If you store the device and cuff, do not place heavy objects
on the device and cuff. Remove the batteries. The cuff line
should not be bent sharply.

10. Technical specifications

Model No.
SBM 18
Measurement
Oscillometric, non-invasive blood pressure
method
measurement on the upper arm
Measurement
Cuff pressure 0-300 mmHg,
range
Systolic 50-280 mmHg,
Diastolic 30-200 mmHg,
Pulse 40-199 beats/minute
Display accuracy
Systolic ± 3 mmHg,
Diastolic ± 3 mmHg,
Pulse ± 5% of the value shown
Measurement
Max. permissible standard deviation
inaccuracy
according to clinical testing:
Systolic 8 mmHg /
Diastolic 8 mmHg
Memory
4 x 30 memory spaces
Dimensions
L 110 mm x W 112 mm x H 53 mm
Weight
Approximately 341 g (without batteries,
with cuff)
Cuff size
22 to 36 cm