Standards; Continuous Sound Pressure Sd2550C; Operating Conditions During Measurement; Measuring Point Configuration - Fayat Group DYNAPAC SD2550C Operating Instructions Manual

Paver finisher
Table of Contents

Advertisement

7
EN standards
7.1

Continuous sound pressure SD2550C

m
The operator always must use ear protection. The emission value at the ear of
the driver varies depending on the materials used for paving and may even rise above
85 dB(A). If no ear protection devices are used, hearing can be impaired.
The sound emission level of the paver finisher was measured under free-field condi-
tions according to EN 500-6:2006 and ISO 4872.
Sound pressure level at the operator's position
(at the height of the head):
Sound capacity level:
Sound pressure level at the vehicle
Measuring point
Sound pressure level L
(dB(A))
7.2

Operating conditions during measurement

The diesel engine was running at maximum speed. The screed was lowered into
working position. The tamper and the vibrator were running at min. 50% of their max-
imum speed, the augers at min. 40% and the conveyors at min. 10% of their maxi-
mum speed.
7.3

Measuring point configuration

Hemispherical measuring surface with a radius of 16 m. The machine was at the cen-
tre. The measuring points had been assigned the following coordinates:
Co-ordinates
B 38
2
AFeq
74.6
Measuring points 2, 4, 6, 8
X
Y
±11.2
±11.2
L
= 87.2
AF
L
= 108.3
WA
4
6
76.0
77.5
78.5
Measuring points 10, 12
Z
X
- 4.32
1.5
+4.32
dB(A)
dB(A)
8
10
12
74.7
74.5
Y
Z
+10.4
11.36
-10.4
11.36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac sd2550cs894895

Table of Contents