Ultrasonic Auger Limit Switches (Left And Right) - Conventional Version - Fayat Group DYNAPAC SD2550C Operating Instructions Manual

Paver finisher
Table of Contents

Advertisement

Ultrasonic
(left and right) - conventional version
The limit switches control the material
A
flow at the relevant half of the auger
without contact.
The ultrasonic sensor (1) is secured to
the side shield via a bracket (2).
- To adjust the sensor angle, loosen the
clamps (3) and swivel the bracket.
- To set the sensor height / the deacti-
vation
point,
handles (4) and adjust the linkage to
the required length.
- After adjusting, retighten all mounting
parts properly.
The connection cables are connected to
A
the relevant sockets on the remote con-
trol bracket.
The sensors should be adjusted so that
A
2/3 of the augers are covered with the
paving material.
The paving material must be conveyed over the full working width.
A
We recommend adjusting the limit switch positions during material distribution.
A
D 30 30
auger
limit
switches
loosen
the
2
4
star
1
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac sd2550cs894895

Table of Contents