Adjusting Upper Shaft Shield Plate Position - Bernina Deco 330 Manual

Hide thumbs Also See for Deco 330:
Table of Contents

Advertisement

Deco 330

Adjusting Upper Shaft Shield Plate Position

The standard height of needle stop position should be 14.2 mm above the needle plate
surface when the machine is topped.
(A)
(B)
5
3
1
2
4
1 Remove the front cover unit. (See page 6)
2 Turn the power switch "ON" and press Start / Stop
button twice.
Stop the machine with the needle in the up position.
3 (A) If the needle stops higher than 14.2 mm, loosen
Screw 1 and turn the Upper shaft shield plate
2 in the direction of (A).
(B) If the needle stops lower than 14.2 mm 3 ,
loosen Screw 1 and turn the Upper shaft
shield plate
2
4 Place the right side of the Upper shaft shield plate 2
in the center of the slit of the Upper shaft sensor
and tighten Setcrew 1 .
5 Press the Start/Stop button twice to check the height
of the needle stop position, then attach the front cover.
1
Screw
2
Upper shaft shield plate
3
14.2 mm
Upper shaft sensor
4
Needle #11
5
13
in the direction of (B).