FIG. 9
Front - Bottom of Unit, See Detail B, Below
Product Rating
Label/Serial Tag
3" Min.
Power
Cord or
Conduit
3-Prong grounding type
receptacle connected to
a properly grounded and
polarized electrical supply
rated at 120VAC, 10 Amps,
( or 15A*) Single Phase,
60 HZ. NOTE: This is not
applicable to 240 VAC
models with 24" electric
griddle. **
*15 Amp 120 VAC electrical supply is required for 36" and
48" models with a 24" electric griddle.
**30 Amp 240 VAC electrical supply is required for models
with a 24" electric griddle.
Step 2: Cabinet Preparation
Threading compounds
must be resistant to Pro-
pane Gas
P24WOK 1/2" NPT
3/4" flex line
gas flow
A manual valve must be
installed external to the
appliance, in an accessible
location from the front, for
the purpose of shutting off
the gas supply.
All Installer supplied parts
must conform to Local Codes.
7