Information:
WARNING - ELECRICAL SHOCK HAZARD
Use extreme caution when drilling holes into the wall or floor. There
may be concealed electrical wires located behind the wall or under
the floor.
Identify the electrical circuits that could be affected by the installa-
tion of the Anti-Tip Device, then turn off power to these circuits.
Failure to follow these instructions may result in electrical shock or
other personal injury.
ATTENTION - PROPERTY DAMAGE
Contact a qualified installer or contractor to determine the proper
method for drilling holes through the wall or floor material (such as
ceramic tile, hardwood, etc.)
Do not slide the range across an unprotected floor.
Failure to follow these instructions may result in damage to wall or
floor coverings.
Tools Needed for Installation of Anti-Tip Device:
Screwdriver, Phillips
Drill, electric or hand
Measuring tape or ruler
1/8" drill bit (wood or metal wall or floor)
Hammer
Pencil or other marker
3/16" carbide-tipped masonry drill bit (concrete or concrete block wall or floor)
3/16" anchors, drywall or concrete, 4 each (not required if mounting bracket is
being attached to solid wood or metal)
For 30" and 36" Dual Fuel Ranges (Figure 6 and Figure 7)
Thermador Service
Part No.
415078
427338
The anti-tip bracket may be attached to a solid wood cabinet having a minimum
wall thickness of 3/4".
The thickness of the wall or floor may require use of longer screws, available at
your local hardware store.
In all cases, at least two (2) of the bracket mounting screws must be fastened to
solid wood or metal.
WARNING
All Ranges can tip
Injury to Persons could result
Install Anti-Tip Device Packed with
Range
See Installation Instructions
Qty
4
Screw, Phillips, #10 x 1-1/2"
1
Anti-Tip Bracket, Floor-Mounted
Description