PASSWORD RESET

Resetting the password resets the Administrator password, network and web server settings to the
original factory default values. The Standard User password is not affected. To reset, do the following:
1. Press and hold the Output Select button on the front of the panel (approximately 20 seconds) until
Resetting is shown on the LCD.
2. Release the button.
3. After reset is complete, press and release the Output Select button once to view the network status
screen on the LCD. The new IP address of the panel will be displayed.

ROUTER CONFIGURATION

This section explains how to set up the panel behind a router and enable remote access to the panel
over the Internet.
A router allows multiple PCs to share a single Internet connection. To enable access to the panel over
the Internet, you will need to configure your router to forward incoming remote data to the local IP
address of your panel.
The following steps use a Linksys WRT54G router as an example.
1. Log in to your router and go to the port forwarding screen. In the Linksys WRT54G, this is located in
the Applications and Gaming tab. The location of port forwarding may be different on other routers
(consult your router manual for instructions).
2. To configure HTTP forwarding, following these steps:
a. Enter a unique name in the Application field.
b. Enter the HTTP port number that the panel is using in the Start and End fields. If you are
using the default panel port settings, the port number is 80.
c. Select Both under Protocol (TCP and UDP).
d. Enter the local IP address of the panel (e.g. 192.168.0.180) in the IP Address field. See
step 2 of Web-based Configuration Utility section to find the actual local IP address of
your panel.
e. Check Enable, and then click on Save Settings.
NOTE:
Many ISPs block access to port 80. If your ISP does block port 80, you will need to change
the HTTP port the panel uses from 80 to something else, such as 8000. Valid port numbers
are in the range of 1 - 65535. See the Network Setup section for instructions on how to
change the panel network ports. You will also need to change the HTTP port number from
80 to something else if your local network already contains another device using port 80
such as another panel or a web server.