Available languages

use. Avoid touching the
inside surface.
• Do not hang towels,
dishcloths or clothes
from the appliance or its
handles.
1.4. During Cleaning
and Maintenance
Always turn the
appliance off before
operations such as
cleaning or
maintenance. You can
do it after plugging the
appliance off or turning
the main switches off.
• Do not remove the
control knobs to clean
the control panel.
• To maintain the
efficiency and safety
of your appliance,
we recommend you
always use original
spare parts and to call
our authorised service
agents in case of need.
2. INSTALLATION AND
PREPARATIONS FOR USE
WARNING: This appliance must be
installed by an authorised service person or
qualified technician, according to the
instructions in this guide and in compliance
with the current local regulations.
• Incorrect installation may cause harm
and damage, for which the manufacturer
accepts no responsibility and the
warranty will not be valid.
• Prior to installation, ensure that the local
distribution conditions (electricity voltage
and frequency and/or nature of the gas
and gas pressure) and the adjustments
of the appliance are compatible. The
adjustment conditions for this appliance
are stated on the label.
• The laws, ordinances, directives and
standards in force in the country of use
are to be followed (safety regulations,
proper recycling in accordance with the
regulations, etc.).

2.1. Instructions for the Installer

Ventilation requirements
• For rooms with a volume of less than
permanent ventilation of 100 cm
5 m
3
free area is required.
• For rooms with a volume of between 5
m
and 10 m
3
50 cm
free area will be required, unless
2
the room has a door which opens
directly the outside air in which case no
permanent ventilation is required.
• For rooms with a volume greater than
10 m
no permanent ventilation is
3
required.
Important: Regardless of room size, all
rooms containing the appliance must have
direct access to outside air via an openable
window or equivalent.
Emptying of the burned gases from
environment
Gas appliances expel burned gas waste
to the outside air, either directly or via a
cooker hood with a chimney. If it is not
possible to install a cooker hood, install a
fan on the window or wall that has access
to fresh air. The fan must have the capacity
to change the volume of air in the kitchen a
minimum of 4-5 times per hour.