Lenze smd401 Operating Instructions Manual page 16

Frequency inverter 0.37 kw...22 kw
Table of Contents

Advertisement

Commissioning
Code
No.
Name
1
Minimum output
frequency
11
Maximum output
frequency
1
Acceleration time 1
1
Deceleration time 1
1
Operating Mode
1
V/f reference point
1
V
boost
min
(optimization of
torque behavior)
17
Frequency threshold
(Q
)
min
1
Chopper frequency
21
Slip compensation
2
Current limit
Accel boost
14
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Possible Settings
Lenze Selection
0.0
0.0
{Hz}
50.0 7.5
{Hz}
WARNING!
Consult motor/machine manufacturer before operating above rated frequency.
Overspeeding the motor/machine may cause damage to equipment and injury to
personnel!
5.0
0.0
{s}
5.0
0.0
{s}
2
0
Linear characteristic with
Auto-Boost
1
Square-law characteristic with
Auto-Boost
2
Linear characteristic with constant
V
boost
min
3
Square-law characteristic with
constant V
boost
min
50.0 25.0
{Hz}
Set the rated motor frequency
(nameplate) for standard applications
4.0
0.0
{%}
Set after commissioning: The unloaded
motor should run at slip frequency
(approx. 5 Hz), increase C16 until
motor current (C54) = 0.8 x rated motor
current
0.0
0.0
{Hz}
2
0
4 kHz
1
6 kHz
2
8 kHz
3
10 kHz
0.0
0.0
{%}
150 30
{%}
Reference: smd rated output current
0.0
0.0
{%}
ENGLISH
IMPORTANT
500
• Output frequency at 0% analog
setpoint
• C10 not active for fixed setpoints or
setpoint selection via c40
500
• Output frequency at 100% analog
setpoint
• C11 is never exceeded
999
• C12 = frequency change 0 Hz...C11
• C13 = frequency change C11...0 Hz
999
• For S-ramp accel/decel, adjust c82
• Linear characteristic: for standard
applications
• Square-law characteristic: for fans
and pumps with square-law load
characteristic
• Auto boost: load-dependent output
voltage for low-loss operation
999
40.0
500
See C08 and c17, selection 7
Reference: setpoint
• As chopper frequency is increased,
motor noise is decreased
• Observe derating in Section 2.2
• Automatic derating to 4 kHz at 1.2 x I
40.0
Change C21 until the motor speed no
longer changes between no load and
maximum load
150
• When the limit value is reached, either
the acceleration time increases or the
output frequency decreases
• When C90 = 2, max setting is 180%
20.0
Accel boost is only active during
acceleration
smd006