See the following troubleshooting table to take measures if any of the phenomena in the table occurs when in the connection with the BluetoothR
Communication Unit.
Status
Communications cannot be established
Files cannot be read from the outside while
the sensor is connected
F3SG-SR does not go back to normal state
after terminating SD Manager 3
* The procedure depends on the device you use for SD Manager 3. Refer to instruction manuals of the device.

Related Manuals

Man.No.
Z405
F3SG-SR--
• The Bluetooth
®
word mark and logo are registered trademarks and are owned by the Bluetooth SIG, Inc. and any use of such mark by OMRON
Corporation is under license.
• USB Type-C™ is a trademark of USB Implementers Forum.
• The product photographs and figures that are used in this catalog may vary somewhat from the actual products.
• Other company names and product names in this document are the trademarks or registered trademarks of their respective companies.
73
Check if Bluetooth
®
Communication Unit is properly mounted.
Check if Bluetooth
®
function is enabled on the device you use for SD Manager 3.
Check if Bluetooth
®
Communication Unit is not being paired with another device.
Check if Bluetooth
®
Communication Unit and the device you use for SD Manager 3 are properly
paired (or the connection is verified). *
Check if Bluetooth
®
function of the device you use for SD Manager 3 supports SPP (Serial Port
Profile).
Check if a COM port is properly configured.
Check the noise level in the environment.
Check if there is any device that uses 2.4 GHz band.
Check if there is any obstruction between Bluetooth
for SD Manager 3. The maximum permissible line-of-sight distance is approximately 10 m.
The F3SG-SR is under the SETTING state. Turn OFF and ON the power of the F3SG-SR.
The sensor model in the saved file does not match the sensor model in the file that you are about to
read in. Check the sensor model.
If a file is saved by SD Manager 3 of a newer version than your SD Manager 3, the file is not usable
on your SD Manager 3. Check the SD Manager 3 version.
Restart F3SG-SR. If SD Manager 3 does not operate normally even after restarted, use the setup
recovery function to restore to the factory default settings again.