Follett Horizon Elite 1412 Installation Instructions Manual page 2

Table of Contents

Advertisement

W1 Width
D1 Depth
H1 Height
Electrical
Minimum circuit ampacity
Maximum overcurrent protection
Outdoor condensing unit operating limits
(air temperature)
Maximum refrigerant line run length
Maximum line rise above evaporator
Evaporator mounting above condenser
Maximum refrigeration line drop without oil trap
Refrigerant charge
Approximate ship weight
Approximate net weight
2
Horizon Elite 1412 series
39.6" (100.6 cm)
28.2" (71.6 cm)
26.0" (66.0 cm)
three phase – 208-230/60/3 (Emerson/Copeland)
three phase – 12A
three phase – 20A
min –20 F (–29 C)
max 120 F (49 C)
100' (30,5 m)
35' (10,7 m)
15' (4,6 m)
15' (4,6 m)
8 lb
three phase – 265 lbs (120.2 kg)
three phase – 230 lbs (104.3 kg)
REMOTE CONDENSING UNIT

Advertisement

Table of Contents
loading

Table of Contents