Practical Advice On How To Use The Burners; Injectors Table - KitchenAid KHMF 9010/I Instructions For Use Manual

Table of Contents

Advertisement

5019_719_01120_GB_STEP_FILO:Layout 1

Practical advice on how to use the burners

Read these instructions to get the best out of your
burners:
- Use pans with a diameter the same as the burner
(see pan diameter table to the side).
- Only use flat bottom pots and pans.
- Use the right amount of water for cooking food
and use the lid.
Important: using the pan supports incorrectly will
scratch the hob top: avoid placing them upside
down or dragging them across the hob.
You should never use:
- Cast iron or steatite stone grills, terracotta pots
or pans.
- Convectors such as metal netting or other.
IMPORTANT
To get the most out of your burner as well as
its flexibility, use it in the positions shown in
the flame regulation symbols indicated in the
diagrams above. The button positions
corresponding with the continuous sections in
the diagram to the right shows maximum
functioning areas and make the most of the
burner's capacity.

Injectors table

Category II2H3+
Type of gas used
Type of
burner
NATURAL GAS
Dual crown
(Methane)
G20
Internal crown
GAS
Dual crown
LIQUID PETROLEUM
(Butane) G30
Internal crown
GAS
Dual crown
LIQUID PETROLEUM
(Propane) G31
Internal crown
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
3,6 kW
Electrical: 230 V - 50 Hz -
19-07-2007
Injector
Injector
Injector
marking
distance
distance
(X) mm
(Y) mm
140 + 34
7,5
-
34
-
open
86 + 13
11
-
13
-
open
86 + 13
11
-
13
-
open
Configuration
Heat flow
model
nominal kW
3 burners
12,60
3 burners
11,34
3 burners
11,34
Type PLMTF
14:03
Pagina 5
- The use of two burners simultaneously with just
one container such as a fish kettle.
Failure comply with these recommendations
could lead to your glass ceramic hob being
damaged, or broken and/or the safety of your
equipment being compromised.
Burner
both crowns
only the internal crown
Nominal heat
Nominal
Reduced heat
flow kW
consumption
flow kW
4,20
400 l/h
0,50
48 l/h
3,78
275 g/h
0,45
33 g/h
3,78
270 g/h
0,45
32 g/h
Total consumption
nominal
1200 l/h
825 g/h
810 g/h
5
Pan diameter
from 24 to 26 cm
from 8 to 14 cm
Gas pressure (mbar)
min.
nom.
max
1,70
17
20
25
0,25
2,65
20
28-30
35
0,25
2,65
25
37
45
0,25
Required air (m
3
)
for the combustion of 1 m
3
of gas
9,52
30,94
23,80

Advertisement

Table of Contents
loading