Magnet switch

Advertisement

Quick Links

Magnet Switch
®
Featuring LoRaWAN
LEO-S595-MSG0 / LEO-S595-MSC0
User Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the LEO-S595-MSG0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Advantech LEO-S595-MSG0

  • Page 1 Magnet Switch ® Featuring LoRaWAN LEO-S595-MSG0 / LEO-S595-MSC0 User Guide...
  • Page 2 Safety Precautions Advantech will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. ❖ The device must not be remodeled in any way. ❖ In order to protect the security of the device, please change device the password when first configuration.
  • Page 3 3.5.1 Upgrade ..........................11 3.5.2 Backup ..........................11 3.5.3 Reset to Factory Default ....................12 4. Installation ............................. 13 5. Device Payload ............................. 13 5.1 Basic Information ........................13 5.2 Sensor Data ..........................14 5.3 Downlink Commands ......................... 15 www.advantech.com...
  • Page 4 LoRaWAN enables encrypted radio transmissions over long distances while consuming very little power. The user can obtain sensor data and view the trend of data change through Advantech IoT Cloud or through the user’s own Application Server 1.2 Features ⚫...
  • Page 5 Green, blink once Press and hold the reset button (internal) for more Reboot Slowly Blinks than 3 seconds Reset to Factory Press and hold the reset button (internal) for more Quickly Blinks Default than 10 seconds 2.4 Dimensions (mm) www.advantech.com...
  • Page 6 2) If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again. 3) LEO-S595-MSG0 can also be configured by ToolBox software via a dedicated NFC reader provided by Advantech, you can also configure it via TTL interface inside the device.
  • Page 7 OTAA and ABP modes are available. Application Key Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823. Device Address DevAddr for ABP mode, default is the 5 to 12 digits of SN. Network Session Nwkskey for ABP mode, default is 5572404C696E6B4C6F52613230313823. www.advantech.com...
  • Page 8 Make sure the channels match the LoRaWAN gateway. If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas. www.advantech.com...
  • Page 9 Reporting interval of magnet, tamper and battery level to network server. Default: 1080mins, Range: 1 - 1080 mins Reporting Interval Note: LEO-S595-MSG0 will also transmit alarm when magnet status is changed or tamper button is activated. LED Indicator Enable or disable the light indicating in chapter 2.3.
  • Page 10 Change Password Change the password for ToolBox App to write this device. 3.4 LoRa D2D Settings LoRa D2D protocol is developed by Advantech and used for setting up transmission among Advantech devices without gateway. When the LoRa D2D setting is enabled, LEO-S595-MSG0 can work as a LoRa D2D controller to send control commands to trigger LoRa D2D agent devices.
  • Page 11 2) Only Android version ToolBox supports the upgrade feature. 3.5.2 Backup LEO-S595-MSG0 supports configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRa frequency band. 1. Go to “Template” page on the App and save current settings as a template. You can also edit the template file.
  • Page 12 Hold on the reset button inside the device for more than 10s. After reset complete, the indicator will blink in green twice and device will reboot. Go to Device->Reset to click “Reset”, then attach smartphone with NFC area Via ToolBox App: to device to complete reset. www.advantech.com...
  • Page 13 All data are based on the following format(HEX): Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3 1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte 5.1 Basic Information LEO-S595-MSG0 reports basic information of sensor whenever joining the network. Channe Type Description www.advantech.com...
  • Page 14 Type Value 0102 (Software (V1.2) (Device Type) (Class A) version) 5.2 Sensor Data LEO-S595-MSG0 reports open/close status and tamper status as follows: ⚫ According to reporting interval; ⚫ When magnet or tamper status has changed. Channel Type Description 75(Battery Level) UINT8, Unit: % 00=>Switch close...
  • Page 15 Channel Type Value (Tamper (Un-installed) Status) 5.3 Downlink Commands LEO-S595-MSG0 supports downlink commands to configure the device. The application port is 85 by default. Channe Type Description 03 (Set Reporting Interval) 2 Bytes, unit: s Example: Set reporting interval as 20 minutes.