060652-45532/16387 - 05/2023
1

Information about this document

1.1

Contents and purpose

1
1
This document supplements the SVA/SVI locks'
1
assembly instructions and contains technical
1
information for the mounting and commissioning of
1
an SVA 6xxx lock.
1
1.2

Target group

2
2
The locks may only be mounted by technical
2
specialists who have been trained for this purpose by
2
dormakaba.
2
1.3

Other applicable documents

2
2
• SVA/SVI locks assembly instructions
3
• Manual for the connecting cable SVP-A 1100/2100
3
• Technical documents for the selected control unit
• Commissioning instructions for the SVI lock
1.4

Abbreviations

3
Active, self-locking
SVA
(anti-)panic lock for the active door leaf
4
in 2-leaf door units
4
Inactive, self-locking (anti-)panic lock for
5
SVI
the passive door leaf in 2-leaf door units
5
5
All versions of a lock; the exact lock type
6xxx
is marked with 3 digits instead of xxx.
6
6
G
Active door leaf
S
Passive door leaf
1.5

Symbols used

Item numbers used in image
1
2
caption
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SVA 6 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba SVA 6 Series

  • Page 1 Intended use The locks may only be mounted by technical 2.2 Non-intended use specialists who have been trained for this purpose by 2.3 Reasonably foreseeable misuse dormakaba. Product description Other applicable documents Parts included 3.2 Door fittings required • SVA/SVI locks assembly instructions 3.3 Technical data...
  • Page 2 In case of emergency, the door can 2-leaf door units. be opened in the escape direction at any time. The • Only use the components approved by dormakaba SVA lock canquery the status of the trip latch, bolt, for mounting: door handle/panic bar and the locking cylinder.
  • Page 3 Commissioning instructions SVA 6xxx Technical data Variants The door must always be opened in the escape Supply voltage: 12 or 24 V DC stabilized direction. (+/- 10 %) Depending on the design and type of mounting, the Temperature range: -25°C to +70°C escape route direction is outwards opening (normal case) or inwards opening (special case).
  • Page 4 R-outwards/L-inwards SVA 6829 70010132 L-outwards/R-inwards SVA 6830 70010133 R-outwards/L-inwards SVA 6839 70010134 Classification Tubular frame locks dormakaba Deutschland GmbH DORMA Platz 1 - 58256 Ennepetal 0432-CPR-00026-97 SVA 6xxx RR 3 X 6 0 M 7 1 EN 14846:2008 DOP_0165 0432-CPR-00026-11 SVA 6xxx RR EN 179:2008 3 7 7...
  • Page 5 Commissioning instructions SVA 6xxx Pin assignment Note Block diagram SVA 6xxx Stand Alone For earthed door frames, the bridge on the SVP-A x100 connection cable’s plug must be Contact definition: Position of the switches when the disconnected. door is closed and locked. Door handle and cylinder not actuated.
  • Page 6 Refer to the statutory regulations for your country. Fig. 2 Change operating current to quiescent current Mounting takes place when the door unit is assembled. See SVA/SVI assembly instructions. https://techdoc.dormakaba.com/cds/go/SVA-SVI SVI commissioning manuals https://techdoc.dormakaba.com/cds/go/SVI 060652-45532 – 05/2023...
  • Page 7 Commissioning instructions SVA 6xxx 060652-45532 – 05/2023...
  • Page 8 Commissioning instructions SVA 6xxx dormakaba Deutschland GmbH | DORMA Platz 1 | 58256 Ennepetal | Germany T: +49 2333 793-0 | www.dormakaba.com...

This manual is also suitable for:

Sva 6000

Table of Contents