Teil 5. Trouble Shooting; Teil 6: Maintenance - involight SLIMPAR710PRO User Manual

Table of Contents

Advertisement

Available languages

Available languages

NOTE:
• When the white LED lit, you are in DMX mode 1: 6 DMX channels
• When the amber LED lit, you are in DMX mode 2: 7 DMX channels
• When the UV LED lit, you are in DMX mode 3: 8 DMX channels
• When the red and green LED lit, you are in DMX mode 4: 9 DMX channels
• When the red and blue LED lit, you are in DMX mode 5: 11 DMX channels
DMX Start-Address setup:
Push CH button to set the DMX address or initialize the program, then the red, green,blue,white,amber and UV
lights will flash 2~3 times. Please put in 3 number,for example, 1 2 3. After the red light is on, please put in the first
number. After the first number is accessed the green light will be on, then put in the second number. When the
blue light will be on, please put in the third number. After all the three number are put in, the red, green ,blue,
white,amber and UV lights will flash 2~3 times, which indicate that the DMX address is right and it go in to the
DMX MODE automatically. If the address is wrong the red light will be on. New DMX address should be put in.

Teil 5. Trouble shooting:

The device does not work, no light:
Check the mains connection and the main fuse.
No response to the DMX controller:
Check the DMX connectors and cables for correct connection. Check the address settings and the DMX polarity.
Check whether the DMX cables are near or next to high voltage cables. Try another DMX controller.
If the instructions given here do not lead to success, please contact your specialist dealer.
Possible disturbances during data transmission
NOTE!
To ensure trouble-free operation, use special DMX cables instead of common microphone cables.
Never connect the DMX output to audio devices such as mixers or amplifiers.

Teil 6: Maintenance:

IMPORTANT: Disconnect the device from the mains before cleaning or do any maintenance work!
Used screws must be tightened tightly and must not show rust marks. The housing, mounting bracket and
mounting location (e.g., ceiling or crossbar) must not be adjusted, i. do not drill additional holes in mounting
brackets, do not alter the connections, etc.
The lenses should be cleaned on a weekly basis, since fog fluid residues settle very quickly, which considerably
reduce the light output of the device.
Use a lint-free, damp cloth for cleaning. Never use alcohol or solvents for cleaning!
There are no serviceable parts inside the device except for the fuse.
Fuse replacement:
IMPORTANT NOTE: Replace the fuse only with the same type and with the same values fuse (printed on the
device). If the fuse breakes often contact an authorized service center.
1: Disconnect the device from the mains and disconnect the power cord from the device.
2: Open the fuse holder on the rear of the device with a suitable screwdriver.
3: Remove the defective fuse from the fuse holder.
4: Insert the new fuse into the fuse holder.
5: Reinstall the fuse holder in the housing.
Maintenance and service work are reserved exclusively for authorized personnel!