Environmental Considerations - Dell PowerEdge XR8610t Installation And Service Manual

Table of Contents

Advertisement

Environmental considerations

The PowerEdge system is targeted for edge deployments and it meets all the additional standards for thermal, shock, and
vibration parameters.
Table 14. Environmental considerations 
Industry
Telco
Military
Marine
Power Industry
Safety
EMC
EMV
Table 15. Maximum shock pulse specifications 
Maximum shock pulse
Operating
Storage
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous
contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage
or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of
the customer.
Table 16. Particulate contamination specifications 
Particulate contamination
Conductive dust
Corrosive dust
Configuration
Description
GR-1089-CORE
Electromagnetic Compatibility and Electrical Safety – Generic Criteria for
Network Telecommunications Equipment
GR-63-CORE
NEBS Requirements: Physical Protection
SR-3580 (NEBS
NEBS Criteria Levels
Level 3)
GR-3108-CORE
Network Equipment in the Outside Plant (OSP). An exception is made
(Class 1)
for cold boot at +5°C instead of -5°C for systems without the heater
subsystem enabled.
N/A
N/A
N/A
N/A
LDV, IEC/EN, CFR, CSA
N/A
EN, CISPR, ES, DTAG, CFR, ICES, VCCI
N/A
RoHS, WEEE, EN, ECE
Specifications
Six consecutively performed shock pulses in the positive and negative x, y,
and z axis of 6 G for up to 11 ms (four pulses on each side on the system)
Six consecutively performed shock pulses in the positive and negative x, y,
and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Specifications
Air must be free of conductive dust, zinc whiskers, or other
conductive particles
NOTE:
This condition applies to data center and non-data center
environments.
● Air must be free of corrosive dust
● Residual dust present in the air must have a deliquescent point less
than 60% relative humidity
NOTE:
This condition applies to data center and non-data center
environments.
Technical specifications
21