Display port

The PowerEdge XR8610t system supports One Mini-DisplayPort on front of the system.

iDRAC port specifications

The PowerEdge XR8610t system supports one RJ45 with port status LEDs for iDRAC remote management (dedicated port
only) on front of the system.

RJ-45 dry contact port

The PowerEdge XR8610t system supports 1 x RJ45 for dry contact on front of the system.
To enhance usage in the IoT space, the XR8610t comes with a dry input sensor. Each input is configurable and manageable in
the iDRAC interface. These are interruptible inputs to iDRAC. Dry means that no energy is supplied to the contacts. The dry
contact connection cable with RJ45 connector on one end is custom to each installation and must be provided by the end user.
Figure 13. iDRAC interface for Dry Input sensors
NOTE:
The RJ45 for dry contact does not support IP function.
The default states of the dry inputs are off/disabled. The user has seven (one for each dry input) enable/disable (default)
control that must be enabled before logging occurs.
Figure 14. Dry input connection diagram
The seven dry inputs are interruptible inputs to iDRAC. They have the following characteristics:
● Monitored by iDRAC for state transition and LC event are for each state transition.
● NOT modeled as IPMI sensors but LC event only sensors. The current state of the input is not monitored or displayed
anywhere.