Environmental Considerations - Dell PowerEdge XR8620t Installation And Service Manual

Table of Contents

Advertisement

Table 17. Maximum vibration specifications
Maximum vibration
Operating
Storage
Table 18. Maximum shock pulse specifications
Maximum shock pulse
Operating
Storage
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any equipment damage or failure from particulates and gaseous
contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage
or failure, you may need to rectify the environmental conditions. Remediation of environmental conditions is the responsibility of
the customer.
Table 19. Particulate contamination specifications
Particulate contamination
Conductive dust
Corrosive dust
Table 20. Gaseous contamination specifications
Gaseous contamination
Copper coupon corrosion rate
Silver coupon corrosion rate

Environmental considerations

The PowerEdge system is targeted for edge deployments and it meets all the additional standards for thermal, shock, vibration
parameters.
Table 21. Environmental considerations
Industry
Telco
20
Technical specifications
Specifications
0.21 G
1.88 G
Specifications
Six consecutively executed shock pulses in the positive and negative x, y,
and z axis of 6 G for up to 11 ms (4 pulse on each side on the system)
Six consecutively executed shock pulses in the positive and negative x, y,
and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
Configuration
Description
GR-1089-CORE
Electromagnetic Compatibility and Electrical Safety – Generic Criteria for
Network Telecommunications Equipment
GR-63-CORE
NEBS Requirements: Physical Protection
SR-3580 (NEBS
NEBS Criteria Levels
Level 3)
at 5 Hz to 500 Hz (all operation orientations)
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
rms
Specifications
Air must be free of conductive dust, zinc whiskers, or other
conductive particles
NOTE:
This condition applies to data center and non-data center
environments.
● Air must be free of corrosive dust
● Residual dust present in the air must have a deliquescent point less
than 60% relative humidity
NOTE:
This condition applies to data center and non-data center
environments.
Specifications
<300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013
<200 Å/month as defined by ANSI/ISA71.04-2013