Lenovo ThinkSystem SD650 Manual page 30

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Update the XCC firmware to a version that the server supports. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code.
• FQXSPBR4002I: Management Controller [arg1] Reset was caused by restoring default values.
This message is for the use case where a Management Controller has been reset due to a user restoring
the configuration to default values.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0032
User Action:
Information only; no action is required
• FQXSPBR4003I: Platform Watchdog Timer expired for [arg1].
This message is for the use case when an implementation has detected a Platform Watchdog Timer
Expired
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - OS Timeout
SNMP Trap ID: 21
CIM Prefix: IMM CIM ID: 0039
User Action:
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the XCC Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
• FQXSPBR4004I: Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2],
OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5].
A user configures Server Timeouts
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0095
User Action:
Information only; no action is required
• FQXSPBR4005I: Management Controller [arg1]: Configuration saved to a file by user [arg2].
A user saves a Management Controller configuration to a file.
26