• D4 : USER_RST_DEFAULT
FPC network related settings were manually cleared and reset to out-of-factory default with one of the
following actions: 1)Press hardware reset button for more than 4s. 2)Click on the "Reset to Default" button
on the FPC web 'Chassis Rear Overview' page. 3)IPMI command to FPC (ipmitool -H IP -U USERID -P
PASSWORD -I lanplus raw 0x32 0xAD).
Severity
Info
Serviceable
Automatically notify support
User Action
1. No user action needed.
• D5 : FPC_POWER_ON
This event assertion indicates that the chassis was ac cycled, FPC was rebooted, or FPC was hot-
swapped.
Severity
Info
Serviceable
Automatically notify support
User Action
1. No user action needed.
• D6 : PS_0_OUTPUT_FAIL
PSU failed to enter zero output mode after 3 re-tries.
Severity
Info
Serviceable
Automatically notify support
User Action
1. No user action needed.
• E0 : LeakSnr1_Missing
For water cool related setup only, this event indicates that drip tray is missing from fan bay#1.
Severity
Critical
Serviceable
Automatically notify support
User Action
Complete the following steps:
1. Ensure both drip trays are installed in fan bay1 and 3 of the chassis.
2. Ensure all connecting cable are plugged properly if trays are installed.
.
247
Chapter 5
FPC events