Lenovo ThinkSystem SD650 Manual page 187

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Parameters:
[arg1]: GPT corruption location, "Primary":Only primary GPT partition table corruption. "Backup":Only
backup GPT partition table corruption. "Both Primary and Backup":Both GPT partition tables corruption
[arg2]: Disk GUID
User Action:
Information only; no action is required.
• FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Connect at least one bootable device to the system.
3. Connect AC power to the system.
4. Power on system and retry.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFTR0001L: An invalid date and time have been detected.
Severity: Warning
User Action:
Complete the following steps:
1. Check the XCC event logs. This event should immediately precede an FQXSFPW0001L error.
Resolve that event or any other battery related errors.
2. Use F1 Setup to reset date and time.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
.