Lenovo ThinkSystem SD650 Manual page 184

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

• FQXSFPU4054G: TPM/TCM card logical binding has failed.
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFPU4056M: TPM/TCM card is changed, need install back the original TCM/TPM card which
shipped with the system.
Severity: Error
User Action:
Complete the following steps:
1. Re-install the original TCM/TPM card that shipped with the system.
2. Reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFPU4080I: Host Power-On password has been changed.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4081I: Host Power-On password has been cleared.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4082I: Host Admin password has been changed.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4083I: Host Admin password has been cleared.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4084I: Host boot order has been changed.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFPU4085I: Host WOL boot order has been changed.