Lenovo ThinkSystem SD650 Manual page 147

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Table 3. Events organized by severity (continued)
Message String
Event ID
FQXSFPU4045G
Physical Presence is not asserted, abort TPM Firmware upgrade.
FQXSFPU4050G
Failed to update TPM Firmware.
FQXSFPU4051G
Undefined TPM_TCM_POLICY found
FQXSFPU4052G
TPM_TCM_POLICY is not locked
FQXSFPU4053G
System TPM_TCM_POLICY does not match the planar.
FQXSFPU4054G
TPM/TCM card logical binding has failed.
FQXSFPW0001L
CMOS has been cleared.
FQXSFSM0002N
Boot Permission denied by Management Module: System Halted.
FQXSFSM0003N
Timed Out waiting on boot permission from Management Module:
System Halted.
FQXSFSM0004M
An XCC communication failure has occurred.
FQXSFSR0001M
[arg1] GPT corruption detected, DiskGUID: [arg2]
FQXSFSR0003G
The number of boot attempts has been exceeded. No bootable
device found.
FQXSFTR0001L
An invalid date and time have been detected.
FQXSFDD0004M
DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required
Controller.
FQXSFDD0012K
SATA Hard Drive Error: [arg1].
FQXSFIO0005M
An intra-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0006M
An inter-board UPI failure has been detected on the link between
processor [arg1] port [arg2] and processor [arg3] port [arg4].
FQXSFIO0007M
An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
FQXSFIO0010M
An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
FQXSFIO0011M
A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The Physical slot number is [arg6].
FQXSFIO0012M
A PCIe system error has occurred on Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The Physical slot number is [arg6].
FQXSFIO0014J
A bad option ROM checksum was detected for the device found at
Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device
is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
FQXSFIO0017M
IFM: Error communicating with the XCC - IFM may not be deployed
correctly.
FQXSFIO0019J
PCIe Resource Conflict.
Severity
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
.
143
Chapter 3
UEFI events

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n12007x585468

Table of Contents