27
ERROR_CAN_SAFETY
28
Cage ERROR_ANALOG
Cage Weigh Channel 1
29
Disconnected
Cage Weigh Channel 2
30
Disconnected
31
Tilt Sensor Disconnected
32
Telescope Switch Error
33
Telescope2 Switch Error
34
Cage ERROR_IO
35
Cage Node off the CANBus
36
Parameter Error
37
Serial Number Error
38
Cage Weigh Error
39
Links Paddle Error
English/USA – 05/15
Original instructions
Fault
The control system has
detected an error in the
communication between the
base and cage
Error on one of the analogue
inputs to the cage PLC
The channel 1 cage weigh
module is disconnected or
faulty
The channel 2 cage weigh
module is disconnected or
faulty
The tilt sensor is disconnected
or faulty
Switch inputs to the PLC do not
oppose or switch in sync
Switch inputs to the PLC do not
oppose or switch in sync
Error on one of the inputs or
outputs of the cage PLC
The base PLC is not receiving
the cage node's 'present' signal
Parameters do not match or
incompatible selections have
been made
Serial numbers in base and
cage PLCs do not match
Cage Weigh inputs to the PLC
do not oppose or switch in
sync
Paddle analogue outputs are
not within spec of each other
Operating & Safety Instructions
Description
Check that there is around 60Ohms
between CANH and CANL anywhere on
the network
Check there are no short circuits
between CANH and CANL anywhere on
the network
Check address dials are set correctly
Check screen for further fault codes
Diagnose further using the service tool
Check the module is connected
Check the wiring from the cage panel
to the module
Check the module is connected
Check the wiring from the cage panel
to the module
Check the sensor is connected
Check the wiring from the base box to
the sensor
Check wiring between switch and PLC
Check switch operation
Check wiring between switch and PLC
Check switch operation
Check screen for further fault codes
Diagnose further using the service tool
Check the power supply to the cage
node
Check the CANBus connections from
the cage panel to the cage node
Check on service tool that parameters
are the same for base and cage
Check that only one type of machine is
selected (e.g. Hybrid, Diesel or
Electric)
Fit correct PLCs
Change serial number in PLCs
Check wiring between cage weigh PCB
and PLC
Check cage weigh PCB operation
Check paddle analogue voltages
Use another paddle to check inputs to
control system
Height Rider/SP Series