4.3.3
INFORMATION ICONS
Safety Critical
Advisory
English/USA – 05/15
Original instructions
Safe Working Load exceeded:- The alarm sounds and the display
alternates between the images shown here. The Maximum SWL
(225kg/500lbs) has been exceeded. Immediately remove any unnecessary
items from the platform in a safe manner to restore machine functions.
Alternatively, the platform may have come into contact with a fixed object,
see Section 5.3 for recovery procedure.
MAX tilt angle exceeded:- The alarm sounds and the display shows this
image. Lower booms into stowed position and drive onto level ground to
fully restore machine operation.
Note:If a Safety Critical condition (red flashing triangle) has been
detected, the safety warning lamp on the Platform Control Panel and Base
Control Panel will also illuminate.
Boom Function Speed: Determined by the Speed Selector switch on the
Cage Control Panel (Refer to Page 25).
Note: If the ambient air temperature is <10°C it is recommended to use
Speed II until the machine has warmed up sufficiently.
Drive Speed: Determined by the Speed Selector switch on the Platform
Control Panel (Refer to Page 25). Digital display reverts to these icons once
the joystick trigger is activated.
Battery Levels Low: Flashing battery icon indicates remaining charge level
is <10%.
Ground Controls: To enable platform controls, selector switch located on
ground controls must be turned clockwise. (Refer to Section 4.2.1, Item 7)