Brake Generator Assembly; Contact Heart Rate Grips Replacement - Lower; Body - Life Fitness Arc Trainer Service Manual

Hide thumbs Also See for Arc Trainer:
Table of Contents

Advertisement

Contact Heart Rate Grips Replacement - Lower Body
Tools Required:
• Phillips screwdriver
• Side cutter
• Tape
Time:
30 minutes
Disconnect Power Source
Unplug power cord from power outlet.
WARNING: Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Remove Rear Cover
1. Remove screws securing console assembly and console back cover to console weldment using a Phillips
screwdriver.
2. Remove grounding screw securing console assembly to console weldment using a Phillips screwdriver.
NOTE: Not all consoles include a grounding screw.
Remove Heart Rate Grips
1. Remove screws securing bottom and top grip to handle using a Phillips screwdriver.
2. Remove end cap from handle.
Item
1
2
3
4
Screw, Pan Head Phillips, M5 x 0.8 x 14
5
Grounding Screw, Pan Head Phillips, M5 x
Item
1
2
3
4
Screw, Pan Head Phillips, 1.12"
5
6
Page 22 of 79
Description
Console Assembly
Console Weldment
Console Back Cover
0.8 x 14
Description
Grip, Heart Rate, Top
Grip, Heart Rate, Bottom
End Cap
Red Heart Rate Wire
Black Heart Rate Wire
Qty
1
1
1
4
1
Qty
1
1
1
4
1
1

Advertisement