5 Reader Parameters
Device Control
5-7-4
Device Control by Serial Command
Disable Reader
Sending <I> will turn the reader OFF, end the current read cycle, and will not allow the reader to enter
another read cycle until turned ON. This feature is useful during extended periods of time when no sym-
bols are being decoded, or the reader is being configured. Disabling the reader will not affect any com-
mands that have already been downloaded.
Enable Reader
Sending <H> will turn the reader ON and allow it to enter read cycles.