4 WebLink
Configuration
HH
Remove Control Characters and Remove Extended Characters – These are used to remove all ASCII
control characters and ASCII extended characters from decoded barcode data. A complete ASCII table is
available for reference here. Control characters are defined as 1-31, and extended characters are defined
as 127-255.
Define Replacements – Replaces normal or ASCII characters in the string with user defined characters.
To use, click on the Replacements in the dialog and it will bring up the following dialog.
Begin by clicking on the + to add a row for each character to be replaced. Complete the table using the
following fields.
Character: The standard or ASCII character that you want to replace.
Replacement Count: How many characters to insert in its place. Valid options are 0, 1, and 2.
Replacement: The character, or characters that you want to replace the character with. These
can be standard or ASCII.
When you replace a character with one or more different characters, the results will be displayed in the
Output Data window in the lower right panel of the WebLink
Up to 25 character replacements can be defined. If duplicates are defined, an error message will appear,
and only the first definition will be applied.
4-58
user interface.