5 Reader Parameters
Read Rate
5-7-2
Read Rate Serial Utility Commands
Enter Decodes/Second Test
Sending <C> instructs the reader to transmit the decodes per second and symbol data (if any). The
decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of
view. This test is very useful in aligning and positioning the reader during setup.
Enter Percent Test
Sending <Cp> instructs the reader to transmit the percentage of decodes and any decoded symbol data.
End Read Rate Test
Sending <J> ends both the Percent test and the Decodes/Second test.
5-64
V460-H Industrial Handheld DPM Reader User Manual