Counters
5-7-3
Counters by Serial Command
No-Read Counter
Sending <N> displays the total number of No-Reads that have occurred since the last reset.
No-Read Counter Reset
Sending <O> sets the No-Read Counter to 0.
Trigger Counter
Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset
Sending <U> sets the trigger counter to 0.
Good Read/Match Counter (or Good Read Counter)
Sending <V> displays the total number of good reads matching the master symbol, or, if Master Sym-
bol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will
only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this
counter records the number of good reads. This count can be requested at any time.
Good Read/Match Counter Reset
Sending <W> sets the Match Counter to 0.
Mismatch Counter
Sending <X> displays the number of decoded symbols since the last reset that do not match the master
symbol.
Mismatch Counter Reset
Sending <Y> sets the Mismatch Counter to 0.
V460-H Industrial Handheld DPM Reader User Manual
5 Reader Parameters
5-65